struct Settings {
|
|
bool debug = DEBUG_BY_DEFAULT;
|
|
char hostname[80] = "opentherm";
|
|
|
|
struct {
|
|
byte inPin = OT_IN_PIN_DEFAULT;
|
|
byte outPin = OT_OUT_PIN_DEFAULT;
|
|
unsigned int memberIdCode = 0;
|
|
bool dhwPresent = true;
|
|
bool summerWinterMode = false;
|
|
bool heatingCh2Enabled = true;
|
|
bool heatingCh1ToCh2 = false;
|
|
bool dhwToCh2 = false;
|
|
bool dhwBlocking = false;
|
|
bool modulationSyncWithHeating = false;
|
|
} opentherm;
|
|
|
|
struct {
|
|
char server[80];
|
|
unsigned short port = 1883;
|
|
char user[32];
|
|
char password[32];
|
|
char prefix[80] = "opentherm";
|
|
unsigned short interval = 5;
|
|
} mqtt;
|
|
|
|
struct {
|
|
bool enable = true;
|
|
float target = 40.0f;
|
|
bool useEquitherm = false;
|
|
bool usePid = false;
|
|
} emergency;
|
|
|
|
struct {
|
|
bool enable = true;
|
|
bool turbo = false;
|
|
float target = 40.0f;
|
|
float hysteresis = 0.5f;
|
|
byte minTemp = DEFAULT_HEATING_MIN_TEMP;
|
|
byte maxTemp = DEFAULT_HEATING_MAX_TEMP;
|
|
byte maxModulation = 100;
|
|
} heating;
|
|
|
|
struct {
|
|
bool enable = true;
|
|
byte target = 40;
|
|
byte minTemp = DEFAULT_DHW_MIN_TEMP;
|
|
byte maxTemp = DEFAULT_DHW_MAX_TEMP;
|
|
} dhw;
|
|
|
|
struct {
|
|
bool enable = false;
|
|
float p_factor = 50;
|
|
float i_factor = 0.006f;
|
|
float d_factor = 10000;
|
|
unsigned short dt = 180;
|
|
byte minTemp = 0;
|
|
byte maxTemp = DEFAULT_HEATING_MAX_TEMP;
|
|
} pid;
|
|
|
|
struct {
|
|
bool enable = false;
|
|
float n_factor = 0.7f;
|
|
float k_factor = 3.0f;
|
|
float t_factor = 2.0f;
|
|
} equitherm;
|
|
|
|
struct {
|
|
struct {
|
|
// 0 - boiler, 1 - manual, 2 - ds18b20
|
|
byte type = 0;
|
|
byte pin = SENSOR_OUTDOOR_PIN_DEFAULT;
|
|
float offset = 0.0f;
|
|
} outdoor;
|
|
|
|
struct {
|
|
// 1 - manual, 2 - ds18b20, 3 - ble
|
|
byte type = 1;
|
|
byte pin = SENSOR_INDOOR_PIN_DEFAULT;
|
|
char bleAddresss[18];
|
|
float offset = 0.0f;
|
|
} indoor;
|
|
} sensors;
|
|
|
|
struct {
|
|
bool use = false;
|
|
byte pin = EXT_PUMP_PIN_DEFAULT;
|
|
unsigned short postCirculationTime = 600;
|
|
unsigned int antiStuckInterval = 2592000;
|
|
unsigned short antiStuckTime = 300;
|
|
} externalPump;
|
|
|
|
char validationValue[8] = SETTINGS_VALID_VALUE;
|
|
} settings;
|
|
|
|
struct Variables {
|
|
struct {
|
|
bool enable = false;
|
|
byte regulator = 0;
|
|
} tuning;
|
|
|
|
struct {
|
|
bool otStatus = false;
|
|
bool emergency = false;
|
|
bool heating = false;
|
|
bool dhw = false;
|
|
bool flame = false;
|
|
bool fault = false;
|
|
bool diagnostic = false;
|
|
} states;
|
|
|
|
struct {
|
|
float modulation = 0.0f;
|
|
float pressure = 0.0f;
|
|
float dhwFlowRate = 0.0f;
|
|
byte faultCode = 0;
|
|
int8_t rssi = 0;
|
|
} sensors;
|
|
|
|
struct {
|
|
float indoor = 0.0f;
|
|
float outdoor = 0.0f;
|
|
float heating = 0.0f;
|
|
float dhw = 0.0f;
|
|
} temperatures;
|
|
|
|
struct {
|
|
bool enable = false;
|
|
unsigned long lastEnableTime = 0;
|
|
} externalPump;
|
|
|
|
struct {
|
|
bool heatingEnabled = false;
|
|
byte heatingMinTemp = DEFAULT_HEATING_MIN_TEMP;
|
|
byte heatingMaxTemp = DEFAULT_HEATING_MAX_TEMP;
|
|
byte heatingSetpoint = 0;
|
|
byte dhwMinTemp = DEFAULT_DHW_MIN_TEMP;
|
|
byte dhwMaxTemp = DEFAULT_DHW_MAX_TEMP;
|
|
byte maxModulation;
|
|
uint8_t slaveMemberId;
|
|
uint8_t slaveFlags;
|
|
uint8_t slaveType;
|
|
uint8_t slaveVersion;
|
|
float slaveOtVersion;
|
|
uint8_t masterMemberId;
|
|
uint8_t masterFlags;
|
|
uint8_t masterType;
|
|
uint8_t masterVersion;
|
|
float masterOtVersion;
|
|
} parameters;
|
|
|
|
struct {
|
|
bool restart = false;
|
|
bool resetFault = false;
|
|
bool resetDiagnostic = false;
|
|
} actions;
|
|
} vars; |