Yurii
0425cdc499
refactor: prohibition of enabling portal auth with an empty login or password
2025-01-14 06:21:32 +03:00
Yurii
17bd31b2a2
feat: added OT option `Sync max heating temp with target temp`
2025-01-05 17:32:10 +03:00
Yurii
527e9cc1d6
feat: added OT option `Heating state as summer/winter mode`
2024-12-25 19:30:09 +03:00
Yurii
0cb361d243
refactor: OT option `heatingCh2Enabled has been renamed to ch2AlwaysEnabled`
2024-12-17 10:30:06 +03:00
Yurii
f439f8c5ba
feat: added OT cooling support flag
...
* refactoring OT settings struct
* renamed some OT settings
2024-12-15 14:24:05 +03:00
Yurii
a5996cc93d
refactor: rounding sensor values
2024-11-15 01:28:28 +03:00
Yurii
9d6b6c18ab
fix: pub network.rssi
2024-11-15 01:18:45 +03:00
Yurii
0d71a674b6
feat: added more OT polled IDs & reformat code
...
* ID79 - exhaust CO2
* ID84 - exhaust fan speed
* ID85 - supply fan speed
* ID29 - solar storage temp
* ID30 - solar collector temp
* ID35 - boiler fan speed setpoint & actual
2024-11-14 23:02:46 +03:00
Yurii
2ff84cbddf
fix: update target heating temp when restoring settings
2024-11-12 11:42:48 +03:00
Yurii
636872f72d
refactor: some fixes
2024-11-12 10:48:29 +03:00
Yurii
c6df74f06e
refactor: optimizations & fixes
2024-11-11 15:45:36 +03:00
Yurii
fda18cdb13
refactor: memory optimization for esp8266
2024-11-11 02:41:39 +03:00
Yurii
e71f3868fd
refactor: dynamic sensors
2024-11-09 17:10:26 +03:00
Yurii
467cfea449
feat: ability to use return heat carrier temp as indoor temp
2024-11-01 04:16:50 +03:00
Yurii
94e8288d76
feat: added entities to HA: connected, rssi, battery, humidity for indoor and outdoor sensors; some entities are disabled by default
2024-11-01 02:36:45 +03:00
Yurii
f86857c279
feat: improved turbo mode
...
- added turbo factor parameter
- implemented turbo mode for PID
2024-10-31 05:22:41 +03:00
Yurii
a6e8953807
refactor: reworked emergency mode; reworked hysteresis algorithm; improved detection of connection state for MANUAL & BOILER type sensors
2024-10-31 01:36:21 +03:00
Yurii
3d11d13631
feat: added crash recorder and ability to save dump
2024-10-24 04:01:14 +03:00
Yurii
87b222e7bc
refactor: increased the max value of dt for pid to 1800 sec
2024-10-21 21:34:53 +03:00
Yurii
7f701a74e7
feat: fault state gpio setting replaced with cascade control
2024-10-18 06:14:09 +03:00
Yurii
57cf98ca19
refactor: cosmetic changes; move maxModulation setting to opentherm section
2024-10-15 05:09:20 +03:00
Yurii
5553a13cc0
feat: added log level setting
2024-10-15 04:07:00 +03:00
Yurii
a9e97c15ad
refactor: more logs; improved sensor of current boiler power: added settings min & max boiler power
2024-10-15 02:10:46 +03:00
Yurii
dc62f99b7d
feat: added polling of min modulation and max boiler power; added sensor for current boiler power
2024-10-14 19:54:26 +03:00
Yurii
45af7a30d8
refactor: cosmetic changes; added coeff. setting for filtering numeric values
2024-10-13 21:42:33 +03:00
Yurii
b0a9460257
feat: added correction coeff. settings for pressure and dhw flow rate
2024-10-11 01:29:50 +03:00
Yurii
3c69f1295e
feat: added opentherm option for filtering numeric values
2024-10-10 21:08:13 +03:00
Yurii
a4ee4c5224
feat: added diagnostic code polling via opentherm, added hex value for fault code and diag code
2024-10-05 10:03:14 +03:00
Yurii
7658aeaa8c
feat: added opentherm option 'immergasFix'
2024-10-01 01:32:35 +03:00
Yurii
1b2bc8e200
feat: added feat use of BLE external sensor; added events onIndoorSensorDisconnect and onOutdoorSensorDisconnect for emergency mode; added polling of rssi, humidity, battery for BLE sensors
2024-08-20 19:06:18 +03:00
Yurii
8b50fdec21
fix: fix typo
2024-06-20 06:41:32 +03:00
Yurii
a825412f37
feat: added fault state GPIO setting
2024-05-25 02:51:10 +03:00
Yurii
8687e122ca
feat: added native heating control by boiler; refactoring; emergency settings removed from HA
2024-04-22 08:18:59 +03:00
Yurii
d35ea81080
fix: PID optimization, correction of default PID settings
2024-04-18 00:04:23 +03:00
Yurii
fbc43dc535
feat: added settings for status led gpio, opentherm rx led gpio, emergency treshold time
2024-04-11 23:53:15 +03:00
Yurii
3dec390cce
feat: many features
...
* added dashboard on portal
* added settings for serial port and telnet
* added on/off settings for mqtt
* added event selection for emergency mode
* refactor html & css
2024-04-11 03:06:56 +03:00
Yurii
92ca257d32
feat: added slave parameters to index page on portal; added poll ID125 (opentherm protocol version)
2024-04-07 22:59:43 +03:00
Yurii
44b6620431
fix: rounding the DHW flow rate value
2024-04-07 19:22:15 +03:00
Yurii
0a8dd2a076
feat: added support unit systems for pressure and flow rate
2024-04-06 18:19:06 +03:00
Yurii
a7a561622e
Merge branch 'unit-system'
2024-04-06 17:38:24 +03:00
Yurii
b0e0f6fd7d
feat: added setting to enable/disable polling of min and max temperatures via opentherm
2024-04-06 15:51:49 +03:00
Yurii
560f8fbd51
feat: optimizing with different unit systems
2024-03-31 02:47:20 +03:00
Yurii
946414ad31
Merge branch 'master' into unit-system
2024-03-31 01:02:59 +03:00
Yurii
f544f01caa
feat: polling of exhaust gas temperature ( #42 ) and heating return temperature; added new sensors to HA
2024-03-30 00:04:51 +03:00
Yurii
2f4dbcc205
feat: added unit system selection
2024-03-20 02:37:20 +03:00
Yurii
a5f6749101
refactor: added SensorType enum
2024-03-14 13:07:42 +03:00
Yurii
b07dd46f55
refactor: optimization
...
* names changed: pin => gpio
* ability to change OpenTherm GPIO without rebooting
2024-03-10 04:10:18 +03:00
Yurii
a5d2b9fcfa
refactor: small fixes
2024-02-20 15:27:51 +03:00
Yurii
280c7f2887
refactor: heap info
2024-01-17 17:51:15 +03:00
Yurii
a9c9457918
refactor: added doc.clear() doc.shrinkToFit() in some code areas
2024-01-14 19:57:25 +03:00