feat: added opentherm option 'immergasFix'

This commit is contained in:
Yurii
2024-10-01 01:32:35 +03:00
parent 790ff5a011
commit 7658aeaa8c
7 changed files with 36 additions and 4 deletions

View File

@@ -79,7 +79,7 @@ public:
}
}
unsigned long setBoilerStatus(bool enableCentralHeating, bool enableHotWater, bool enableCooling, bool enableOutsideTemperatureCompensation, bool enableCentralHeating2, bool summerWinterMode, bool dhwBlocking) {
unsigned long setBoilerStatus(bool enableCentralHeating, bool enableHotWater, bool enableCooling, bool enableOutsideTemperatureCompensation, bool enableCentralHeating2, bool summerWinterMode, bool dhwBlocking, uint8_t lb = 0) {
unsigned int data = enableCentralHeating
| (enableHotWater << 1)
| (enableCooling << 2)
@@ -87,7 +87,9 @@ public:
| (enableCentralHeating2 << 4)
| (summerWinterMode << 5)
| (dhwBlocking << 6);
data <<= 8;
data |= lb;
return this->sendRequest(buildRequest(
OpenThermMessageType::READ_DATA,

View File

@@ -165,6 +165,16 @@ protected:
heatingCh2Enabled = settings.opentherm.dhwPresent && settings.dhw.enable;
}
// Set boiler status LB
// Some boilers require this, although this is against protocol
uint8_t statusLb = 0;
// Immergas fix
// https://arduino.ru/forum/programmirovanie/termostat-opentherm-na-esp8266?page=15#comment-649392
if (settings.opentherm.immergasFix) {
statusLb = 0xCA;
}
unsigned long response = this->instance->setBoilerStatus(
heatingEnabled,
settings.opentherm.dhwPresent && settings.dhw.enable,
@@ -172,7 +182,8 @@ protected:
settings.opentherm.nativeHeatingControl,
heatingCh2Enabled,
settings.opentherm.summerWinterMode,
settings.opentherm.dhwBlocking
settings.opentherm.dhwBlocking,
statusLb
);
if (!CustomOpenTherm::isValidResponse(response)) {

View File

@@ -63,6 +63,7 @@ struct Settings {
bool modulationSyncWithHeating = false;
bool getMinMaxTemp = true;
bool nativeHeatingControl = false;
bool immergasFix = false;
} opentherm;
struct {

View File

@@ -354,6 +354,7 @@ void settingsToJson(const Settings& src, JsonVariant dst, bool safe = false) {
dst["opentherm"]["modulationSyncWithHeating"] = src.opentherm.modulationSyncWithHeating;
dst["opentherm"]["getMinMaxTemp"] = src.opentherm.getMinMaxTemp;
dst["opentherm"]["nativeHeatingControl"] = src.opentherm.nativeHeatingControl;
dst["opentherm"]["immergasFix"] = src.opentherm.immergasFix;
dst["mqtt"]["enable"] = src.mqtt.enable;
dst["mqtt"]["server"] = src.mqtt.server;
@@ -800,6 +801,15 @@ bool jsonToSettings(const JsonVariantConst src, Settings& dst, bool safe = false
}
}
if (src["opentherm"]["immergasFix"].is<bool>()) {
bool value = src["opentherm"]["immergasFix"].as<bool>();
if (value != dst.opentherm.immergasFix) {
dst.opentherm.immergasFix = value;
changed = true;
}
}
// mqtt
if (src["mqtt"]["enable"].is<bool>()) {

View File

@@ -269,7 +269,8 @@
"dhwToCh2": "Duplicate DHW to CH2",
"dhwBlocking": "DHW blocking",
"modulationSyncWithHeating": "Sync modulation with heating",
"getMinMaxTemp": "Get min/max temp from boiler"
"getMinMaxTemp": "Get min/max temp from boiler",
"immergasFix": "Fix for Immergas boilers"
},
"faultState": {

View File

@@ -269,7 +269,8 @@
"dhwToCh2": "Дублировать параметры ГВС в канал 2",
"dhwBlocking": "DHW blocking",
"modulationSyncWithHeating": "Синхронизировать модуляцию с отоплением",
"getMinMaxTemp": "Получать мин. и макс. температуру от котла"
"getMinMaxTemp": "Получать мин. и макс. температуру от котла",
"immergasFix": "Фикс для котлов Immergas"
},
"faultState": {

View File

@@ -443,6 +443,11 @@
<span data-i18n>settings.ot.options.getMinMaxTemp</span>
</label>
<label for="opentherm-immergas-fix"></label>
<input type="checkbox" id="opentherm-immergas-fix" name="opentherm[immergasFix]" value="true">
<span data-i18n>settings.ot.options.immergasFix</span>
</label>
<hr />
<fieldset>
<label for="opentherm-fault-state-gpio">
@@ -736,6 +741,7 @@
setCheckboxValue('#opentherm-sync-modulation-with-heating', data.opentherm.modulationSyncWithHeating);
setCheckboxValue('#opentherm-get-min-max-temp', data.opentherm.getMinMaxTemp);
setCheckboxValue('#opentherm-native-heating-control', data.opentherm.nativeHeatingControl);