mirror of
https://github.com/Laxilef/OTGateway.git
synced 2025-12-11 02:34:29 +05:00
rename methods
This commit is contained in:
@@ -76,18 +76,24 @@ public:
|
||||
return buildRequest(OpenThermMessageType::READ_DATA, OpenThermMessageID::Status, data);
|
||||
}
|
||||
|
||||
bool setBoilerTemperature(float temperature) {
|
||||
bool setHeatingCh1Temp(float temperature) {
|
||||
unsigned int data = temperatureToData(temperature);
|
||||
unsigned long response = sendRequest(buildRequest(OpenThermMessageType::WRITE_DATA, OpenThermMessageID::TSet, data));
|
||||
return isValidResponse(response);
|
||||
}
|
||||
|
||||
bool setBoilerTemperature2(float temperature) {
|
||||
bool setHeatingCh2Temp(float temperature) {
|
||||
unsigned int data = temperatureToData(temperature);
|
||||
unsigned long response = sendRequest(buildRequest(OpenThermMessageType::WRITE_DATA, OpenThermMessageID::TsetCH2, data));
|
||||
return isValidResponse(response);
|
||||
}
|
||||
|
||||
bool setDHWTemp(float temperature) {
|
||||
unsigned int data = temperatureToData(temperature);
|
||||
unsigned long response = sendRequest(buildRequest(OpenThermMessageType::WRITE_DATA, OpenThermMessageID::TdhwSet, data));
|
||||
return isValidResponse(response);
|
||||
}
|
||||
|
||||
bool sendBoilerReset() {
|
||||
unsigned int data = 1;
|
||||
data <<= 8;
|
||||
|
||||
@@ -215,7 +215,7 @@ protected:
|
||||
Log.sinfoln("OT.DHW", "Set temp = %u", newDHWTemp);
|
||||
|
||||
// Записываем заданную температуру ГВС
|
||||
if (ot->setDHWSetpoint(newDHWTemp)) {
|
||||
if (ot->setDHWTemp(newDHWTemp)) {
|
||||
currentDHWTemp = newDHWTemp;
|
||||
dhwSetTempTime = millis();
|
||||
|
||||
@@ -230,7 +230,7 @@ protected:
|
||||
Log.sinfoln("OT.HEATING", "Set temp = %u", vars.parameters.heatingSetpoint);
|
||||
|
||||
// Записываем заданную температуру
|
||||
if (ot->setBoilerTemperature(vars.parameters.heatingSetpoint)) {
|
||||
if (ot->setHeatingCh1Temp(vars.parameters.heatingSetpoint)) {
|
||||
currentHeatingTemp = vars.parameters.heatingSetpoint;
|
||||
heatingSetTempTime = millis();
|
||||
|
||||
@@ -239,7 +239,7 @@ protected:
|
||||
}
|
||||
|
||||
if (settings.opentherm.heatingCh1ToCh2) {
|
||||
if (!ot->setBoilerTemperature2(vars.parameters.heatingSetpoint)) {
|
||||
if (!ot->setHeatingCh2Temp(vars.parameters.heatingSetpoint)) {
|
||||
Log.swarningln("OT.HEATING", "Failed set ch2 temp");
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue