fix: fixed thermostat temperature limits for different unit systems on dashboard

This commit is contained in:
Yurii
2024-04-12 02:03:43 +03:00
parent db2faad741
commit a026a962f0

View File

@@ -202,10 +202,20 @@
window.onload = async function () {
document.querySelector('#thermostat-heating-minus').addEventListener('click', (event) => {
if (!prevSettings) {
return;
}
newSettings.heating.target -= 0.5;
modifiedTime = Date.now();
const minTemp = noRegulators ? prevSettings.heating.minTemp : 5;
let minTemp;
if (noRegulators) {
minTemp = prevSettings.heating.minTemp;
} else {
minTemp = prevSettings.system.unitSystem == 0 ? 5 : 41;
}
if (prevSettings && newSettings.heating.target < minTemp) {
newSettings.heating.target = minTemp;
}
@@ -214,10 +224,20 @@
});
document.querySelector('#thermostat-heating-plus').addEventListener('click', (event) => {
if (!prevSettings) {
return;
}
newSettings.heating.target += 0.5;
modifiedTime = Date.now();
const maxTemp = noRegulators ? prevSettings.heating.maxTemp : 30;
let maxTemp;
if (noRegulators) {
maxTemp = prevSettings.heating.maxTemp;
} else {
maxTemp = prevSettings.system.unitSystem == 0 ? 30 : 86;
}
if (prevSettings && newSettings.heating.target > maxTemp) {
newSettings.heating.target = maxTemp;
}
@@ -226,10 +246,14 @@
});
document.querySelector('#thermostat-dhw-minus').addEventListener('click', (event) => {
if (!prevSettings) {
return;
}
newSettings.dhw.target -= 1;
modifiedTime = Date.now();
if (prevSettings && newSettings.dhw.target < prevSettings.dhw.minTemp) {
if (newSettings.dhw.target < prevSettings.dhw.minTemp) {
newSettings.dhw.target = prevSettings.dhw.minTemp;
}
@@ -237,10 +261,14 @@
});
document.querySelector('#thermostat-dhw-plus').addEventListener('click', (event) => {
if (!prevSettings) {
return;
}
newSettings.dhw.target += 1;
modifiedTime = Date.now();
if (prevSettings && newSettings.dhw.target > prevSettings.dhw.maxTemp) {
if (newSettings.dhw.target > prevSettings.dhw.maxTemp) {
newSettings.dhw.target = prevSettings.dhw.maxTemp;
}