fix: added C/F temperature conversion in overheating protection

This commit is contained in:
Yurii
2025-06-20 02:46:25 +03:00
parent b985275309
commit 58b0c18448

View File

@@ -1320,11 +1320,15 @@ protected:
// Heating overheat control
if (settings.heating.overheatHighTemp > 0 && settings.heating.overheatLowTemp > 0) {
float highTemp = max({
vars.slave.heating.currentTemp,
vars.slave.heating.returnTemp,
vars.slave.heatExchangerTemp
});
float highTemp = convertTemp(
max({
vars.slave.heating.currentTemp,
vars.slave.heating.returnTemp,
vars.slave.heatExchangerTemp
}),
settings.opentherm.unitSystem,
settings.system.unitSystem
);
if (vars.master.heating.overheat) {
if ((float) settings.heating.overheatLowTemp - highTemp + 0.0001f >= 0.0f) {
@@ -1353,14 +1357,18 @@ protected:
// DHW overheat control
if (settings.dhw.overheatHighTemp > 0 && settings.dhw.overheatLowTemp > 0) {
float highTemp = max({
vars.slave.heating.currentTemp,
vars.slave.heating.returnTemp,
vars.slave.heatExchangerTemp,
vars.slave.dhw.currentTemp,
vars.slave.dhw.currentTemp2,
vars.slave.dhw.returnTemp
});
float highTemp = convertTemp(
max({
vars.slave.heating.currentTemp,
vars.slave.heating.returnTemp,
vars.slave.heatExchangerTemp,
vars.slave.dhw.currentTemp,
vars.slave.dhw.currentTemp2,
vars.slave.dhw.returnTemp
}),
settings.opentherm.unitSystem,
settings.system.unitSystem
);
if (vars.master.dhw.overheat) {
if ((float) settings.dhw.overheatLowTemp - highTemp + 0.0001f >= 0.0f) {