mirror of
https://github.com/Laxilef/OTGateway.git
synced 2025-12-10 18:24:27 +05:00
fix: fix set heating temp on ITALTHERM TIME MAX 30F
This commit is contained in:
@@ -383,19 +383,28 @@ protected:
|
||||
float convertedTemp = convertTemp(vars.parameters.heatingSetpoint, settings.system.unitSystem, settings.opentherm.unitSystem);
|
||||
Log.sinfoln(FPSTR(L_OT_HEATING), F("Set temp: %u (converted: %.2f)"), vars.parameters.heatingSetpoint, convertedTemp);
|
||||
|
||||
// Set heating temp
|
||||
if (this->instance->setHeatingCh1Temp(convertedTemp) || this->setMaxHeatingTemp(convertedTemp)) {
|
||||
// Set max heating temp
|
||||
if (this->setMaxHeatingTemp(convertedTemp)) {
|
||||
currentHeatingTemp = vars.parameters.heatingSetpoint;
|
||||
this->heatingSetTempTime = millis();
|
||||
|
||||
} else {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set temp"));
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set max heating temp"));
|
||||
}
|
||||
|
||||
// Set heating temp
|
||||
if (this->instance->setHeatingCh1Temp(convertedTemp)) {
|
||||
currentHeatingTemp = vars.parameters.heatingSetpoint;
|
||||
this->heatingSetTempTime = millis();
|
||||
|
||||
} else {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set CH1 temp"));
|
||||
}
|
||||
|
||||
// Set heating temp to CH2
|
||||
if (settings.opentherm.heatingCh1ToCh2) {
|
||||
if (!this->instance->setHeatingCh2Temp(convertedTemp)) {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set ch2 temp"));
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set CH2 temp"));
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue