fix: fix set heating temp on ITALTHERM TIME MAX 30F

This commit is contained in:
Yurii
2024-04-15 15:00:41 +03:00
parent 646939179e
commit 41ce9b268e

View File

@@ -383,19 +383,28 @@ protected:
float convertedTemp = convertTemp(vars.parameters.heatingSetpoint, settings.system.unitSystem, settings.opentherm.unitSystem);
Log.sinfoln(FPSTR(L_OT_HEATING), F("Set temp: %u (converted: %.2f)"), vars.parameters.heatingSetpoint, convertedTemp);
// Set heating temp
if (this->instance->setHeatingCh1Temp(convertedTemp) || this->setMaxHeatingTemp(convertedTemp)) {
// Set max heating temp
if (this->setMaxHeatingTemp(convertedTemp)) {
currentHeatingTemp = vars.parameters.heatingSetpoint;
this->heatingSetTempTime = millis();
} else {
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set temp"));
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set max heating temp"));
}
// Set heating temp
if (this->instance->setHeatingCh1Temp(convertedTemp)) {
currentHeatingTemp = vars.parameters.heatingSetpoint;
this->heatingSetTempTime = millis();
} else {
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set CH1 temp"));
}
// Set heating temp to CH2
if (settings.opentherm.heatingCh1ToCh2) {
if (!this->instance->setHeatingCh2Temp(convertedTemp)) {
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set ch2 temp"));
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set CH2 temp"));
}
}
}