updated process description
This commit is contained in:
@@ -1843,6 +1843,16 @@
|
||||
)
|
||||
(uuid "43a737a9-02e8-438e-84ac-abcb1a7268bc")
|
||||
)
|
||||
(wire
|
||||
(pts
|
||||
(xy 38.1 41.91) (xy 41.91 41.91)
|
||||
)
|
||||
(stroke
|
||||
(width 1)
|
||||
(type dash)
|
||||
)
|
||||
(uuid "45e1518f-ee16-4a72-9988-51d9ca021561")
|
||||
)
|
||||
(wire
|
||||
(pts
|
||||
(xy 133.35 60.96) (xy 135.89 60.96)
|
||||
@@ -1973,6 +1983,16 @@
|
||||
)
|
||||
(uuid "6c444678-32cd-4b69-be56-46eeab3472bb")
|
||||
)
|
||||
(wire
|
||||
(pts
|
||||
(xy 38.1 134.62) (xy 43.18 134.62)
|
||||
)
|
||||
(stroke
|
||||
(width 1)
|
||||
(type dash)
|
||||
)
|
||||
(uuid "720474cb-9426-4cf8-ac63-23b15db4b508")
|
||||
)
|
||||
(wire
|
||||
(pts
|
||||
(xy 104.14 83.82) (xy 104.14 86.36)
|
||||
@@ -2063,6 +2083,16 @@
|
||||
)
|
||||
(uuid "93bd9c54-62da-4bd2-a4dc-1764939b651e")
|
||||
)
|
||||
(wire
|
||||
(pts
|
||||
(xy 38.1 41.91) (xy 38.1 134.62)
|
||||
)
|
||||
(stroke
|
||||
(width 1)
|
||||
(type dash)
|
||||
)
|
||||
(uuid "96f8de2e-2061-42ad-8a12-3778b628af90")
|
||||
)
|
||||
(wire
|
||||
(pts
|
||||
(xy 171.45 55.88) (xy 176.53 55.88)
|
||||
@@ -3559,7 +3589,7 @@
|
||||
"rkJggg=="
|
||||
)
|
||||
)
|
||||
(text "Process\n-------\nRecieve input height sensing signal\nActivate dc-dc converter\n - 24V DC will appear on the dc-dc converter output\n - A small current will flow through via 100 kOhm resistor (shorted output)\n - Relay will activate\n - Connection between work piece ground and torch shield ground is broken\n - Output will be unshorted, current through resistor stops flowing\n - 23V voltage appears between electrode and work piece ground\nWait a few tenths of a second to allow realy to settle before monitoring gap voltage\nWhen Arc voltage > x V: send contact Signal (repeat signal x times?)\n exit sensing mode\nAfter x msecs: exit sensing mode\nLoss of height sensing signal: exit sensing mode\n\nExit of sensing mode: disable height sensings voltage. This releases relay and shuts off sensing voltage.\n\n"
|
||||
(text "Process\n-------\nRecieve input height sensing signal\nActivate dc-dc converter\n - 24V DC will appear on the dc-dc converter output\n - A small current will flow through via 100 kOhm resistor (shorted output)\n - Relay will activate\n - Connection between work piece ground and torch shield ground is broken\n - Output will be unshorted, current through resistor stops flowing\n - 23V voltage appears between electrode and work piece ground\nWait a few tenths of a second to allow relay to settle before monitoring gap voltage\nWhen Arc voltage < x V: raise contact Signal\nLoss of height sensing signal: exit sensing mode, lower contact Signal\n\n"
|
||||
(exclude_from_sim no)
|
||||
(at 88.646 131.826 0)
|
||||
(effects
|
||||
|
||||
Reference in New Issue
Block a user