mirror of
https://github.com/Laxilef/OTGateway.git
synced 2026-11-25 07:43:04 +05:00
Use threshold_time for the emergency-mode delay in settings, JSON, portal forms and all five translations. Convert legacy tresholdTime backup fields to threshold_time. Correct the NTC voltage threshold macro names while keeping their limits.
456 lines
14 KiB
C++
456 lines
14 KiB
C++
#define LOG_LOCAL_LEVEL ESP_LOG_VERBOSE
|
|
|
|
#include <app.h>
|
|
|
|
#include <algorithm>
|
|
|
|
Variables vars;
|
|
|
|
enum class PumpStartReason {NONE, HEATING, ANTISTUCK};
|
|
|
|
static bool heatingEnabled = false;
|
|
static unsigned long heatingDisabledTime = 0;
|
|
static PumpStartReason extPumpStartReason = PumpStartReason::NONE;
|
|
static unsigned long externalPumpStartTime = 0;
|
|
static bool emergencyDetected = false;
|
|
static unsigned long emergencyFlipTime = 0;
|
|
|
|
static Task freezeProtectionTask("Freeze protection", [](void*) {
|
|
float lowTemp = 255.0f;
|
|
uint8_t availableSensors = 0;
|
|
|
|
if (Sensors::existsConnectedSensorsByPurpose(Sensors::Purpose::INDOOR_TEMP)) {
|
|
auto value = Sensors::getMeanValueByPurpose(Sensors::Purpose::INDOOR_TEMP, Sensors::ValueType::PRIMARY, settings.heating.indoorTempAvgType);
|
|
if (value < lowTemp) {
|
|
lowTemp = value;
|
|
}
|
|
|
|
availableSensors++;
|
|
}
|
|
|
|
if (Sensors::existsConnectedSensorsByPurpose(Sensors::Purpose::HEATING_TEMP)) {
|
|
auto value = Sensors::getMeanValueByPurpose(Sensors::Purpose::HEATING_TEMP, Sensors::ValueType::PRIMARY);
|
|
if (value < lowTemp) {
|
|
lowTemp = value;
|
|
}
|
|
|
|
availableSensors++;
|
|
}
|
|
|
|
if (Sensors::existsConnectedSensorsByPurpose(Sensors::Purpose::HEATING_RETURN_TEMP)) {
|
|
auto value = Sensors::getMeanValueByPurpose(Sensors::Purpose::HEATING_RETURN_TEMP, Sensors::ValueType::PRIMARY);
|
|
if (value < lowTemp) {
|
|
lowTemp = value;
|
|
}
|
|
|
|
availableSensors++;
|
|
}
|
|
|
|
if (availableSensors) {
|
|
if (vars.master.heating.freezing) {
|
|
if (lowTemp - static_cast<float>(settings.heating.freezeProtection.highTemp) + 0.0001f >= 0.0f) {
|
|
vars.master.heating.freezing = false;
|
|
|
|
ESP_LOGI(
|
|
L_MAIN,
|
|
"No freezing detected. Current low temp: %.2f, threshold (high): %hhu",
|
|
lowTemp, settings.heating.freezeProtection.highTemp
|
|
);
|
|
}
|
|
|
|
} else {
|
|
if (static_cast<float>(settings.heating.freezeProtection.lowTemp) - lowTemp + 0.0001f >= 0.0f) {
|
|
vars.master.heating.freezing = true;
|
|
|
|
if (!settings.heating.enabled) {
|
|
settings.heating.enabled = true;
|
|
requestSaveSettings();
|
|
}
|
|
|
|
ESP_LOGI(
|
|
L_MAIN,
|
|
"Freezing detected! Current low temp: %.2f, threshold (low): %hhu",
|
|
lowTemp, settings.heating.freezeProtection.lowTemp
|
|
);
|
|
}
|
|
}
|
|
|
|
} else if (vars.master.heating.freezing) {
|
|
vars.master.heating.freezing = false;
|
|
|
|
ESP_LOGI(L_MAIN, "No sensors available, freeze protection unavailable!");
|
|
}
|
|
});
|
|
|
|
static Task emergencyTask("Emergency mode", [](void*) {
|
|
// flags
|
|
uint8_t emergencyFlags = 0b00000000;
|
|
|
|
// set outdoor sensor flag
|
|
if (settings.equitherm.enabled) {
|
|
if (!Sensors::existsConnectedSensorsByPurpose(Sensors::Purpose::OUTDOOR_TEMP)) {
|
|
emergencyFlags |= 0b00000001;
|
|
}
|
|
}
|
|
|
|
// set indoor sensor flags
|
|
if (!Sensors::existsConnectedSensorsByPurpose(Sensors::Purpose::INDOOR_TEMP)) {
|
|
if (!settings.equitherm.enabled && settings.pid.enabled) {
|
|
emergencyFlags |= 0b00000010;
|
|
}
|
|
|
|
if (settings.opentherm.options.nativeOTC) {
|
|
emergencyFlags |= 0b00000100;
|
|
}
|
|
}
|
|
|
|
// if any flags is true
|
|
if ((emergencyFlags & 0b00001111) != 0) {
|
|
if (!emergencyDetected) {
|
|
// flip flag
|
|
emergencyDetected = true;
|
|
emergencyFlipTime = millis();
|
|
|
|
} else if (emergencyDetected && !vars.emergency.state) {
|
|
// enable emergency
|
|
if (millis() - emergencyFlipTime > (settings.emergency.thresholdTime * 1000)) {
|
|
vars.emergency.state = true;
|
|
ESP_LOGI(L_MAIN, "Emergency mode enabled (%hhu)", emergencyFlags);
|
|
}
|
|
}
|
|
|
|
} else {
|
|
if (emergencyDetected) {
|
|
// flip flag
|
|
emergencyDetected = false;
|
|
emergencyFlipTime = millis();
|
|
|
|
} else if (!emergencyDetected && vars.emergency.state) {
|
|
// disable emergency
|
|
if (millis() - emergencyFlipTime > (settings.emergency.thresholdTime * 1000)) {
|
|
vars.emergency.state = false;
|
|
ESP_LOGI(L_MAIN, "Emergency mode disabled");
|
|
}
|
|
}
|
|
}
|
|
});
|
|
|
|
static Task overheatProtectionTask("Overheat protection", [](void*) {
|
|
// Heating overheat control
|
|
if (settings.heating.overheatProtection.highTemp > 0 && settings.heating.overheatProtection.lowTemp > 0) {
|
|
const float highTemp = std::max({
|
|
vars.slave.heating.currentTemp,
|
|
vars.slave.heating.returnTemp,
|
|
vars.slave.heatExchangerTemp
|
|
});
|
|
|
|
if (vars.master.heating.overheat) {
|
|
if (static_cast<float>(settings.heating.overheatProtection.lowTemp) - highTemp + 0.0001f >= 0.0f) {
|
|
vars.master.heating.overheat = false;
|
|
|
|
ESP_LOGI(
|
|
L_OT_HEATING, "Overheating not detected. Current high temp: %.2f, threshold (low): %hhu",
|
|
highTemp, settings.heating.overheatProtection.lowTemp
|
|
);
|
|
}
|
|
|
|
} else if (vars.slave.heating.active) {
|
|
if (highTemp - static_cast<float>(settings.heating.overheatProtection.highTemp) + 0.0001f >= 0.0f) {
|
|
vars.master.heating.overheat = true;
|
|
|
|
ESP_LOGW(
|
|
L_OT_HEATING, "Overheating detected! Current high temp: %.2f, threshold (high): %hhu",
|
|
highTemp, settings.heating.overheatProtection.highTemp
|
|
);
|
|
}
|
|
}
|
|
|
|
} else if (vars.master.heating.overheat) {
|
|
vars.master.heating.overheat = false;
|
|
}
|
|
|
|
// DHW overheat control
|
|
if (settings.dhw.overheatProtection.highTemp > 0 && settings.dhw.overheatProtection.lowTemp > 0) {
|
|
const float highTemp = std::max({
|
|
vars.slave.heating.currentTemp,
|
|
vars.slave.heating.returnTemp,
|
|
vars.slave.heatExchangerTemp,
|
|
vars.slave.dhw.currentTemp,
|
|
vars.slave.dhw.currentTemp2,
|
|
vars.slave.dhw.returnTemp
|
|
});
|
|
|
|
if (vars.master.dhw.overheat) {
|
|
if (static_cast<float>(settings.dhw.overheatProtection.lowTemp) - highTemp + 0.0001f >= 0.0f) {
|
|
vars.master.dhw.overheat = false;
|
|
|
|
ESP_LOGI(
|
|
L_OT_DHW, "Overheating not detected. Current high temp: %.2f, threshold (low): %hhu",
|
|
highTemp, settings.dhw.overheatProtection.lowTemp
|
|
);
|
|
}
|
|
|
|
} else if (vars.slave.dhw.active) {
|
|
if (highTemp - static_cast<float>(settings.dhw.overheatProtection.highTemp) + 0.0001f >= 0.0f) {
|
|
vars.master.dhw.overheat = true;
|
|
|
|
ESP_LOGW(
|
|
L_OT_DHW, "Overheating detected! Current high temp: %.2f, threshold (high): %hhu",
|
|
highTemp, settings.dhw.overheatProtection.highTemp
|
|
);
|
|
}
|
|
}
|
|
|
|
} else if (vars.master.dhw.overheat) {
|
|
vars.master.dhw.overheat = false;
|
|
}
|
|
});
|
|
|
|
static Task cascadeTask("Cascade", [](void*) {
|
|
static uint8_t configuredInputGpio = GPIO_IS_NOT_CONFIGURED;
|
|
static uint8_t configuredOutputGpio = GPIO_IS_NOT_CONFIGURED;
|
|
static bool pendingInputState = false;
|
|
static unsigned long inputChangedTime = 0;
|
|
static bool pendingOutputState = false;
|
|
static unsigned long outputChangedTime = 0;
|
|
|
|
// input
|
|
if (settings.cascadeControl.input.enabled) {
|
|
if (settings.cascadeControl.input.gpio != configuredInputGpio) {
|
|
if (configuredInputGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
// Keep the old input high-impedance, including input-only GPIOs.
|
|
pinMode(configuredInputGpio, INPUT);
|
|
|
|
ESP_LOGI(L_CASCADE_INPUT, "Deinitialized on GPIO %hhu", configuredInputGpio);
|
|
}
|
|
|
|
if (GPIO_IS_VALID_INPUT(settings.cascadeControl.input.gpio)) {
|
|
configuredInputGpio = settings.cascadeControl.input.gpio;
|
|
pinMode(configuredInputGpio, INPUT);
|
|
|
|
ESP_LOGI(L_CASCADE_INPUT, "Initialized on GPIO %hhu", configuredInputGpio);
|
|
|
|
} else if (configuredInputGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
configuredInputGpio = GPIO_IS_NOT_CONFIGURED;
|
|
|
|
ESP_LOGW(L_CASCADE_INPUT, "Failed initialize: GPIO %hhu is not valid!", configuredInputGpio);
|
|
}
|
|
}
|
|
|
|
if (configuredInputGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
bool value = (digitalRead(configuredInputGpio) == HIGH) ^ settings.cascadeControl.input.invertState;
|
|
|
|
if (value != vars.cascadeControl.input) {
|
|
if (value != pendingInputState) {
|
|
pendingInputState = value;
|
|
inputChangedTime = millis();
|
|
|
|
} else if (millis() - inputChangedTime >= settings.cascadeControl.input.thresholdTime * 1000u) {
|
|
vars.cascadeControl.input = value;
|
|
|
|
ESP_LOGI(
|
|
L_CASCADE_INPUT,
|
|
"State changed to %s",
|
|
value ? "TRUE" : "FALSE"
|
|
);
|
|
}
|
|
|
|
} else if (value != pendingInputState) {
|
|
pendingInputState = value;
|
|
}
|
|
}
|
|
}
|
|
|
|
if (!settings.cascadeControl.input.enabled || configuredInputGpio == GPIO_IS_NOT_CONFIGURED) {
|
|
if (!vars.cascadeControl.input) {
|
|
vars.cascadeControl.input = true;
|
|
|
|
ESP_LOGI(
|
|
L_CASCADE_INPUT,
|
|
"Disabled, state changed to %s",
|
|
vars.cascadeControl.input ? "TRUE" : "FALSE"
|
|
);
|
|
}
|
|
}
|
|
|
|
|
|
// output
|
|
if (settings.cascadeControl.output.gpio != configuredOutputGpio) {
|
|
if (configuredOutputGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
digitalWrite(configuredOutputGpio, LOW);
|
|
pinMode(configuredOutputGpio, DISABLED);
|
|
|
|
ESP_LOGI(L_CASCADE_OUTPUT, "Deinitialized on GPIO %hhu", configuredOutputGpio);
|
|
}
|
|
|
|
if (GPIO_IS_VALID_OUTPUT(settings.cascadeControl.output.gpio)) {
|
|
configuredOutputGpio = settings.cascadeControl.output.gpio;
|
|
pinMode(configuredOutputGpio, OUTPUT);
|
|
|
|
ESP_LOGI(L_CASCADE_OUTPUT, "Initialized on GPIO %hhu", configuredOutputGpio);
|
|
|
|
} else if (configuredOutputGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
configuredOutputGpio = GPIO_IS_NOT_CONFIGURED;
|
|
|
|
ESP_LOGW(L_CASCADE_OUTPUT, "Failed initialize: GPIO %hhu is not valid!", configuredOutputGpio);
|
|
}
|
|
}
|
|
|
|
if (settings.cascadeControl.output.enabled) {
|
|
if (configuredOutputGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
bool value = false;
|
|
if (settings.cascadeControl.output.onFault && vars.slave.fault.active) {
|
|
value = true;
|
|
|
|
} else if (settings.cascadeControl.output.onLossConnection && !vars.slave.connected) {
|
|
value = true;
|
|
|
|
} else if (settings.cascadeControl.output.onEnabledHeating && settings.heating.enabled && vars.cascadeControl.input) {
|
|
value = true;
|
|
}
|
|
|
|
if (value != vars.cascadeControl.output) {
|
|
if (value != pendingOutputState) {
|
|
pendingOutputState = value;
|
|
outputChangedTime = millis();
|
|
|
|
} else if (millis() - outputChangedTime >= settings.cascadeControl.output.thresholdTime * 1000u) {
|
|
vars.cascadeControl.output = value;
|
|
|
|
ESP_LOGI(
|
|
L_CASCADE_OUTPUT,
|
|
"State changed to %s",
|
|
value ? "TRUE" : "FALSE"
|
|
);
|
|
}
|
|
|
|
} else if (value != pendingOutputState) {
|
|
pendingOutputState = value;
|
|
}
|
|
}
|
|
}
|
|
|
|
if (!settings.cascadeControl.output.enabled || configuredOutputGpio == GPIO_IS_NOT_CONFIGURED) {
|
|
if (vars.cascadeControl.output) {
|
|
vars.cascadeControl.output = false;
|
|
|
|
ESP_LOGI(
|
|
L_CASCADE_OUTPUT,
|
|
"Disabled, state changed to %s",
|
|
vars.cascadeControl.output ? "TRUE" : "FALSE"
|
|
);
|
|
}
|
|
}
|
|
|
|
if (configuredOutputGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
digitalWrite(
|
|
configuredOutputGpio,
|
|
(vars.cascadeControl.output ^ settings.cascadeControl.output.invertState) ? HIGH : LOW
|
|
);
|
|
}
|
|
});
|
|
|
|
static Task externalPumpTask("External pump", [](void*) {
|
|
static uint8_t configuredGpio = GPIO_IS_NOT_CONFIGURED;
|
|
|
|
if (settings.externalPump.gpio != configuredGpio) {
|
|
if (configuredGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
digitalWrite(configuredGpio, LOW);
|
|
pinMode(configuredGpio, DISABLED);
|
|
}
|
|
|
|
if (GPIO_IS_VALID_OUTPUT(settings.externalPump.gpio)) {
|
|
configuredGpio = settings.externalPump.gpio;
|
|
pinMode(configuredGpio, OUTPUT);
|
|
|
|
} else if (configuredGpio != GPIO_IS_NOT_CONFIGURED) {
|
|
configuredGpio = GPIO_IS_NOT_CONFIGURED;
|
|
}
|
|
}
|
|
|
|
if (configuredGpio == GPIO_IS_NOT_CONFIGURED) {
|
|
if (vars.externalPump.state) {
|
|
vars.externalPump.state = false;
|
|
vars.externalPump.lastEnabledTime = millis();
|
|
|
|
ESP_LOGI(L_EXTPUMP, "Disabled: use = off");
|
|
}
|
|
|
|
return;
|
|
}
|
|
|
|
if (!vars.master.heating.enabled && heatingEnabled) {
|
|
heatingEnabled = false;
|
|
heatingDisabledTime = millis();
|
|
|
|
} else if (vars.master.heating.enabled && !heatingEnabled) {
|
|
heatingEnabled = true;
|
|
}
|
|
|
|
if (!settings.externalPump.use) {
|
|
if (vars.externalPump.state) {
|
|
vars.externalPump.state = false;
|
|
vars.externalPump.lastEnabledTime = millis();
|
|
|
|
ESP_LOGI(L_EXTPUMP, "Disabled: use = off");
|
|
}
|
|
|
|
} else if (vars.externalPump.state && !heatingEnabled) {
|
|
if (extPumpStartReason == PumpStartReason::HEATING && millis() - heatingDisabledTime > (settings.externalPump.postCirculationTime * 1000u)) {
|
|
vars.externalPump.state = false;
|
|
vars.externalPump.lastEnabledTime = millis();
|
|
|
|
ESP_LOGI(L_EXTPUMP, "Disabled: expired post circulation time");
|
|
|
|
} else if (extPumpStartReason == PumpStartReason::ANTISTUCK && millis() - externalPumpStartTime >= (settings.externalPump.antiStuckTime * 1000u)) {
|
|
vars.externalPump.state = false;
|
|
vars.externalPump.lastEnabledTime = millis();
|
|
|
|
ESP_LOGI(L_EXTPUMP, "Disabled: expired anti stuck time");
|
|
}
|
|
|
|
} else if (vars.externalPump.state && heatingEnabled && extPumpStartReason == PumpStartReason::ANTISTUCK) {
|
|
extPumpStartReason = PumpStartReason::HEATING;
|
|
|
|
} else if (!vars.externalPump.state && heatingEnabled) {
|
|
vars.externalPump.state = true;
|
|
externalPumpStartTime = millis();
|
|
extPumpStartReason = PumpStartReason::HEATING;
|
|
|
|
ESP_LOGI(L_EXTPUMP, "Enabled: heating on");
|
|
|
|
} else if (!vars.externalPump.state && (vars.externalPump.lastEnabledTime == 0 || millis() - vars.externalPump.lastEnabledTime >= (settings.externalPump.antiStuckInterval * 1000lu))) {
|
|
vars.externalPump.state = true;
|
|
externalPumpStartTime = millis();
|
|
extPumpStartReason = PumpStartReason::ANTISTUCK;
|
|
|
|
ESP_LOGI(L_EXTPUMP, "Enabled: anti stuck");
|
|
}
|
|
|
|
digitalWrite(
|
|
configuredGpio,
|
|
(vars.externalPump.state ^ settings.externalPump.invertState) ? HIGH : LOW
|
|
);
|
|
});
|
|
|
|
void initControl() {
|
|
freezeProtectionTask.setInterval(1000);
|
|
coreTaskManager.addTask(freezeProtectionTask);
|
|
|
|
emergencyTask.setInterval(1000);
|
|
coreTaskManager.addTask(emergencyTask);
|
|
|
|
// The OpenTherm loop previously skipped overheat control while disconnected.
|
|
overheatProtectionTask.setEnabledWhen([] {
|
|
return vars.slave.connected;
|
|
});
|
|
overheatProtectionTask.setInterval(1000);
|
|
coreTaskManager.addTask(overheatProtectionTask);
|
|
|
|
cascadeTask.setInterval(1000);
|
|
coreTaskManager.addTask(cascadeTask);
|
|
|
|
externalPumpTask.setInterval(1000);
|
|
coreTaskManager.addTask(externalPumpTask);
|
|
}
|