#define LOG_LOCAL_LEVEL ESP_LOG_VERBOSE #include #include #include static GyverPID pidRegulator(0, 0, 0); static float prevHeatingTarget = 0.0f; static float equithermResult = 0.0f; static float pidResult = 0.0f; static bool indoorSensorsConnected = false; static Task equithermTask("Equitherm", Task::Type::ONCE, [](void*) { float etResult = settings.heating.target + settings.equitherm.shift; if (settings.heating.maxTemp > settings.heating.target) { float tempDelta = settings.heating.target - vars.master.heating.outdoorTemp; float maxPoint = settings.heating.target - ( settings.heating.maxTemp - settings.heating.target ) / settings.equitherm.slope; float sf = (settings.heating.maxTemp - settings.heating.target) / pow( settings.heating.target - maxPoint, 1.0f / settings.equitherm.exponent ); etResult = settings.heating.target + settings.equitherm.shift + sf * ( tempDelta >= 0 ? pow(tempDelta, 1.0f / settings.equitherm.exponent) : -(pow(-(tempDelta), 1.0f / settings.equitherm.exponent)) ); } if (indoorSensorsConnected && !settings.pid.enabled && !settings.heating.turbo) { etResult += constrain( settings.heating.target - vars.master.heating.indoorTemp, -3.0f, 3.0f ) * settings.equitherm.targetDiffFactor; } if (!std::isfinite(etResult)) { etResult = settings.heating.target + settings.equitherm.shift; } etResult = constrain(etResult, settings.heating.minTemp, settings.heating.maxTemp); if (isFloatDifferent(equithermResult, etResult, 0.09f)) { equithermResult = etResult; ESP_LOGI(L_REGULATOR_EQUITHERM, "New result: %.2f", etResult); } }); static Task pidTask("PID", Task::Type::FOREVER, [](void*) { pidRegulator.Kp = settings.heating.turbo ? 0.0f : settings.pid.p_factor; pidRegulator.Ki = settings.pid.i_factor; pidRegulator.Kd = settings.pid.d_factor; pidRegulator.setLimits(settings.pid.minTemp, settings.pid.maxTemp); // Use the same period for scheduling and the integral/derivative terms. pidRegulator.setDt(pidTask.interval()); pidRegulator.input = vars.master.heating.indoorTemp; pidRegulator.setpoint = settings.heating.target; float error = pidRegulator.setpoint - pidRegulator.input; bool hasDeadband = settings.pid.deadband.enabled && (error > -(settings.pid.deadband.thresholdHigh)) && (error < settings.pid.deadband.thresholdLow); if (hasDeadband) { pidRegulator.Kp *= settings.pid.deadband.p_multiplier; pidRegulator.Ki *= settings.pid.deadband.i_multiplier; pidRegulator.Kd *= settings.pid.deadband.d_multiplier; } float result = pidRegulator.getResult(); if (isFloatDifferent(pidResult, result, 0.09f)) { pidResult = result; ESP_LOGI(L_REGULATOR_PID, "New result: %.2f", result); ESP_LOGD(L_REGULATOR_PID, "Integral: %.2f", pidRegulator.integral); } }); static void turbo() { if (settings.heating.turbo) { if (!settings.heating.enabled || vars.emergency.state || !indoorSensorsConnected) { settings.heating.turbo = false; } else if (!settings.pid.enabled && !settings.equitherm.enabled) { settings.heating.turbo = false; } else if (fabsf(settings.heating.target - vars.master.heating.indoorTemp) <= 1.0f) { settings.heating.turbo = false; } if (!settings.heating.turbo) { ESP_LOGI(L_REGULATOR, "Turbo mode auto disabled"); } } } static void hysteresis() { // Hysteresis also clears blocking when it is no longer applicable. const bool useHysteresis = settings.heating.hysteresis.enabled && indoorSensorsConnected && (settings.equitherm.enabled || settings.pid.enabled || settings.opentherm.options.nativeOTC); if (useHysteresis) { if (!vars.master.heating.blocking && vars.master.heating.indoorTemp - settings.heating.target + 0.0001f >= settings.heating.hysteresis.value) { vars.master.heating.blocking = true; } else if (vars.master.heating.blocking && vars.master.heating.indoorTemp - settings.heating.target - 0.0001f <= -(settings.heating.hysteresis.value)) { vars.master.heating.blocking = false; } } else if (vars.master.heating.blocking) { vars.master.heating.blocking = false; } } static inline float getHeatingMinSetpointTemp() { return settings.opentherm.options.nativeOTC ? vars.master.heating.minTemp : settings.heating.minTemp; } static inline float getHeatingMaxSetpointTemp() { return settings.opentherm.options.nativeOTC ? vars.master.heating.maxTemp : settings.heating.maxTemp; } static float getHeatingSetpointTemp() { if (isFloatDifferent(prevHeatingTarget, settings.heating.target, 0.0001f)) { prevHeatingTarget = settings.heating.target; ESP_LOGI(L_REGULATOR, "New target: %.2f", settings.heating.target); } if (vars.emergency.state) { return settings.emergency.target; } else if (settings.opentherm.options.nativeOTC) { return settings.heating.target; } float setpoint = settings.heating.target; if (settings.equitherm.enabled || settings.pid.enabled) { setpoint = 0.0f; if (settings.equitherm.enabled) { equithermTask.forceRun(); setpoint += equithermResult; } // Keep the last PID result when heating or the indoor sensor is unavailable. if (settings.pid.enabled) { setpoint += pidResult; } if (settings.heating.turbo) { setpoint += constrain( settings.heating.target - vars.master.heating.indoorTemp, -3.0f, 3.0f ) * settings.heating.turboFactor; } } if (vars.master.heating.freezing) { setpoint = fmaxf( setpoint, static_cast(settings.heating.freezeProtection.lowTemp) ); } return setpoint; } static Task regulatorTask("Regulator", [](void*) { indoorSensorsConnected = Sensors::existsConnectedSensorsByPurpose(Sensors::Purpose::INDOOR_TEMP); if (pidTask.enabled()) { const uint32_t pidInterval = settings.pid.dt * 1000u; if (pidTask.interval() != pidInterval) { pidTask.setInterval(pidInterval); } } if (settings.equitherm.enabled || settings.pid.enabled || settings.opentherm.options.nativeOTC) { vars.master.heating.smartControl = true; vars.master.heating.minTemp = THERMOSTAT_INDOOR_MIN_TEMP; vars.master.heating.maxTemp = THERMOSTAT_INDOOR_MAX_TEMP; } else { vars.master.heating.smartControl = false; vars.master.heating.minTemp = settings.heating.minTemp; vars.master.heating.maxTemp = settings.heating.maxTemp; } // This must still run when the PID calculation task is disabled. if (!settings.pid.enabled && fabsf(pidRegulator.integral) > 0.01f) { pidRegulator.integral = 0.0f; ESP_LOGI(L_REGULATOR_PID, "Integral sum has been reset"); } turbo(); hysteresis(); vars.master.heating.targetTemp = settings.heating.target; const float setpointTemp = getHeatingSetpointTemp(); vars.master.heating.setpointTemp = roundf(constrain( setpointTemp, getHeatingMinSetpointTemp(), getHeatingMaxSetpointTemp() ), 0); Sensors::setValueByType( Sensors::Type::HEATING_SETPOINT_TEMP, vars.master.heating.setpointTemp, Sensors::ValueType::PRIMARY, true, true ); }); void initRegulator() { regulatorTask.setInterval(10000); // Sensor availability is refreshed by the regulator before checking PID eligibility. pidTask.setEnabledWhen([] { return settings.pid.enabled && settings.heating.enabled && !vars.emergency.state && !settings.opentherm.options.nativeOTC && indoorSensorsConnected; }); pidTask.setInterval(10000); pidTask.resume(pidTask.interval()); // Apply mode changes and turbo auto-disable before a PID calculation due on the same pass. coreTaskManager.addTask(regulatorTask); coreTaskManager.addTask(pidTask); coreTaskManager.addTask(equithermTask); equithermTask.pause(); }