mirror of
https://github.com/Laxilef/OTGateway.git
synced 2025-12-11 10:44:29 +05:00
Improve opentherm handling
* First try setBoilerStatus, if it fails there is no need to request other info * Do not retry to get/set non-essential parameters that the boiler does not support
This commit is contained in:
@@ -23,6 +23,10 @@ protected:
|
|||||||
unsigned short heatingSetTempInterval = 60000;
|
unsigned short heatingSetTempInterval = 60000;
|
||||||
|
|
||||||
bool pump = true;
|
bool pump = true;
|
||||||
|
bool tryGetSlaveVersion = true;
|
||||||
|
bool trySetMasterVersion = true;
|
||||||
|
bool tryGetSlaveConfig = true;
|
||||||
|
bool trySetMasterConfig = true;
|
||||||
unsigned long prevUpdateNonEssentialVars = 0;
|
unsigned long prevUpdateNonEssentialVars = 0;
|
||||||
unsigned long startupTime = millis();
|
unsigned long startupTime = millis();
|
||||||
unsigned long dhwSetTempTime = 0;
|
unsigned long dhwSetTempTime = 0;
|
||||||
@@ -61,39 +65,6 @@ protected:
|
|||||||
static byte currentHeatingTemp, currentDhwTemp = 0;
|
static byte currentHeatingTemp, currentDhwTemp = 0;
|
||||||
unsigned long localResponse;
|
unsigned long localResponse;
|
||||||
|
|
||||||
if (millis() - prevUpdateNonEssentialVars > 60000) {
|
|
||||||
if (updateSlaveVersion()) {
|
|
||||||
Log.straceln(FPSTR(S_OT), F("Slave version: %u, type: %u"), vars.parameters.slaveVersion, vars.parameters.slaveType);
|
|
||||||
|
|
||||||
} else {
|
|
||||||
Log.swarningln(FPSTR(S_OT), F("Get slave version failed"));
|
|
||||||
}
|
|
||||||
|
|
||||||
// 0x013F
|
|
||||||
if (setMasterVersion(0x3F, 0x01)) {
|
|
||||||
Log.straceln(FPSTR(S_OT), F("Master version: %u, type: %u"), vars.parameters.masterVersion, vars.parameters.masterType);
|
|
||||||
|
|
||||||
} else {
|
|
||||||
Log.swarningln(FPSTR(S_OT), F("Set master version failed"));
|
|
||||||
}
|
|
||||||
|
|
||||||
if (updateSlaveConfig()) {
|
|
||||||
Log.straceln(FPSTR(S_OT), F("Slave member id: %u, flags: %u"), vars.parameters.slaveMemberId, vars.parameters.slaveFlags);
|
|
||||||
|
|
||||||
} else {
|
|
||||||
Log.swarningln(FPSTR(S_OT), F("Get slave config failed"));
|
|
||||||
}
|
|
||||||
|
|
||||||
if (setMasterConfig(settings.opentherm.memberIdCode & 0xFF, (settings.opentherm.memberIdCode & 0xFFFF) >> 8)) {
|
|
||||||
Log.straceln(FPSTR(S_OT), F("Master member id: %u, flags: %u"), vars.parameters.masterMemberId, vars.parameters.masterFlags);
|
|
||||||
|
|
||||||
} else {
|
|
||||||
Log.swarningln(FPSTR(S_OT), F("Set master config failed"));
|
|
||||||
}
|
|
||||||
|
|
||||||
//yield();
|
|
||||||
}
|
|
||||||
|
|
||||||
bool heatingEnabled = (vars.states.emergency || settings.heating.enable) && pump && isReady();
|
bool heatingEnabled = (vars.states.emergency || settings.heating.enable) && pump && isReady();
|
||||||
bool heatingCh2Enabled = settings.opentherm.heatingCh2Enabled;
|
bool heatingCh2Enabled = settings.opentherm.heatingCh2Enabled;
|
||||||
if (settings.opentherm.heatingCh1ToCh2) {
|
if (settings.opentherm.heatingCh1ToCh2) {
|
||||||
@@ -115,6 +86,11 @@ protected:
|
|||||||
|
|
||||||
if (!ot->isValidResponse(localResponse)) {
|
if (!ot->isValidResponse(localResponse)) {
|
||||||
Log.swarningln(FPSTR(S_OT), F("Invalid response after setBoilerStatus: %s"), ot->statusToString(ot->getLastResponseStatus()));
|
Log.swarningln(FPSTR(S_OT), F("Invalid response after setBoilerStatus: %s"), ot->statusToString(ot->getLastResponseStatus()));
|
||||||
|
// Boiler is disconnected, try to get these variables when it becomes connected again
|
||||||
|
bool tryGetSlaveVersion = true;
|
||||||
|
bool trySetMasterVersion = true;
|
||||||
|
bool tryGetSlaveConfig = true;
|
||||||
|
bool trySetMasterConfig = true;
|
||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -130,8 +106,53 @@ protected:
|
|||||||
vars.states.fault = ot->isFault(localResponse);
|
vars.states.fault = ot->isFault(localResponse);
|
||||||
vars.states.diagnostic = ot->isDiagnostic(localResponse);
|
vars.states.diagnostic = ot->isDiagnostic(localResponse);
|
||||||
|
|
||||||
|
// These parameters will be updated every minute
|
||||||
|
// Not all boilers support these, so only try once if not supported
|
||||||
|
if (millis() - prevUpdateNonEssentialVars > 60000) {
|
||||||
|
if (tryGetSlaveVersion) {
|
||||||
|
if (updateSlaveVersion()) {
|
||||||
|
Log.straceln(FPSTR(S_OT), F("Slave version: %u, type: %u"), vars.parameters.slaveVersion, vars.parameters.slaveType);
|
||||||
|
|
||||||
|
} else {
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Get slave version failed"));
|
||||||
|
tryGetSlaveVersion = false;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
// 0x013F
|
||||||
|
if (trySetMasterVersion) {
|
||||||
|
if (setMasterVersion(0x3F, 0x01)) {
|
||||||
|
Log.straceln(FPSTR(S_OT), F("Master version: %u, type: %u"), vars.parameters.masterVersion, vars.parameters.masterType);
|
||||||
|
|
||||||
|
} else {
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Set master version failed"));
|
||||||
|
trySetMasterVersion = false;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
if (tryGetSlaveConfig) {
|
||||||
|
if (updateSlaveConfig()) {
|
||||||
|
Log.straceln(FPSTR(S_OT), F("Slave member id: %u, flags: %u"), vars.parameters.slaveMemberId, vars.parameters.slaveFlags);
|
||||||
|
|
||||||
|
} else {
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Get slave config failed"));
|
||||||
|
tryGetSlaveConfig = false;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
if (trySetMasterConfig) {
|
||||||
|
if (setMasterConfig(settings.opentherm.memberIdCode & 0xFF, (settings.opentherm.memberIdCode & 0xFFFF) >> 8)) {
|
||||||
|
Log.straceln(FPSTR(S_OT), F("Master member id: %u, flags: %u"), vars.parameters.masterMemberId, vars.parameters.masterFlags);
|
||||||
|
|
||||||
|
} else {
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Set master config failed"));
|
||||||
|
trySetMasterConfig = false;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
//yield();
|
||||||
|
}
|
||||||
|
|
||||||
//
|
|
||||||
// These parameters will be updated every minute
|
// These parameters will be updated every minute
|
||||||
if (millis() - prevUpdateNonEssentialVars > 60000) {
|
if (millis() - prevUpdateNonEssentialVars > 60000) {
|
||||||
if (!heatingEnabled && settings.opentherm.modulationSyncWithHeating) {
|
if (!heatingEnabled && settings.opentherm.modulationSyncWithHeating) {
|
||||||
|
|||||||
Reference in New Issue