refactor: reworked emergency mode; reworked hysteresis algorithm; improved detection of connection state for MANUAL & BOILER type sensors
This commit is contained in:
@@ -208,11 +208,6 @@
|
||||
<div id="emergency-settings-busy" aria-busy="true"></div>
|
||||
<form action="/api/settings" id="emergency-settings" class="hidden">
|
||||
<fieldset>
|
||||
<label for="emergency-enable">
|
||||
<input type="checkbox" id="emergency-enable" name="emergency[enable]" value="true">
|
||||
<span data-i18n>settings.enable</span>
|
||||
</label>
|
||||
|
||||
<small data-i18n>settings.emergency.desc</small>
|
||||
</fieldset>
|
||||
|
||||
@@ -229,43 +224,6 @@
|
||||
</label>
|
||||
</div>
|
||||
|
||||
<fieldset>
|
||||
<legend data-i18n>settings.emergency.events.desc</legend>
|
||||
|
||||
<label for="emergency-on-network-fault">
|
||||
<input type="checkbox" id="emergency-on-network-fault" name="emergency[onNetworkFault]" value="true">
|
||||
<span data-i18n>settings.emergency.events.network</span>
|
||||
</label>
|
||||
|
||||
<label for="emergency-on-mqtt-fault">
|
||||
<input type="checkbox" id="emergency-on-mqtt-fault" name="emergency[onMqttFault]" value="true">
|
||||
<span data-i18n>settings.emergency.events.mqtt</span>
|
||||
</label>
|
||||
|
||||
<label for="emergency-on-indoor-sensor-disconnect">
|
||||
<input type="checkbox" id="emergency-on-indoor-sensor-disconnect" name="emergency[onIndoorSensorDisconnect]" value="true">
|
||||
<span data-i18n>settings.emergency.events.indoorSensorDisconnect</span>
|
||||
</label>
|
||||
|
||||
<label for="emergency-on-outdoor-sensor-disconnect">
|
||||
<input type="checkbox" id="emergency-on-outdoor-sensor-disconnect" name="emergency[onOutdoorSensorDisconnect]" value="true">
|
||||
<span data-i18n>settings.emergency.events.outdoorSensorDisconnect</span>
|
||||
</label>
|
||||
</fieldset>
|
||||
|
||||
<fieldset>
|
||||
<legend data-i18n>settings.emergency.regulators.desc</legend>
|
||||
|
||||
<label for="emergency-use-equitherm">
|
||||
<input type="checkbox" id="emergency-use-equitherm" name="emergency[useEquitherm]" value="true">
|
||||
<span data-i18n>settings.emergency.regulators.equitherm</span>
|
||||
</label>
|
||||
<label for="emergency-use-pid">
|
||||
<input type="checkbox" id="emergency-use-pid" name="emergency[usePid]" value="true">
|
||||
<span data-i18n>settings.emergency.regulators.pid</span>
|
||||
</label>
|
||||
</fieldset>
|
||||
|
||||
<button type="submit" data-i18n>button.save</button>
|
||||
</form>
|
||||
</div>
|
||||
@@ -358,6 +316,8 @@
|
||||
</label>
|
||||
</div>
|
||||
|
||||
<small data-i18n>settings.pid.noteMinMaxTemp</small>
|
||||
|
||||
<button type="submit" data-i18n>button.save</button>
|
||||
</form>
|
||||
</div>
|
||||
@@ -958,18 +918,20 @@
|
||||
setBusy('#dhw-settings-busy', '#dhw-settings', false);
|
||||
|
||||
// Emergency mode
|
||||
setCheckboxValue('#emergency-enable', data.emergency.enable);
|
||||
setInputValue('#emergency-treshold-time', data.emergency.tresholdTime);
|
||||
setCheckboxValue('#emergency-use-equitherm', data.emergency.useEquitherm);
|
||||
setCheckboxValue('#emergency-use-pid', data.emergency.usePid);
|
||||
setCheckboxValue('#emergency-on-network-fault', data.emergency.onNetworkFault);
|
||||
setCheckboxValue('#emergency-on-mqtt-fault', data.emergency.onMqttFault);
|
||||
setCheckboxValue('#emergency-on-indoor-sensor-disconnect', data.emergency.onIndoorSensorDisconnect);
|
||||
setCheckboxValue('#emergency-on-outdoor-sensor-disconnect', data.emergency.onOutdoorSensorDisconnect);
|
||||
setInputValue('#emergency-target', data.emergency.target, {
|
||||
"min": (!data.emergency.useEquitherm && !data.emergency.usePid) ? data.heating.minTemp : 10,
|
||||
"max": (!data.emergency.useEquitherm && !data.emergency.usePid) ? data.heating.maxTemp : 30,
|
||||
});
|
||||
if (data.opentherm.nativeHeatingControl) {
|
||||
setInputValue('#emergency-target', data.emergency.target, {
|
||||
"min": data.system.unitSystem == 0 ? 5 : 41,
|
||||
"max": data.system.unitSystem == 0 ? 30 : 86
|
||||
});
|
||||
|
||||
} else {
|
||||
setInputValue('#emergency-target', data.emergency.target, {
|
||||
"min": data.heating.minTemp,
|
||||
"max": data.heating.maxTemp,
|
||||
});
|
||||
}
|
||||
|
||||
setBusy('#emergency-settings-busy', '#emergency-settings', false);
|
||||
|
||||
// Equitherm
|
||||
@@ -986,12 +948,12 @@
|
||||
setInputValue('#pid-d-factor', data.pid.d_factor);
|
||||
setInputValue('#pid-dt', data.pid.dt);
|
||||
setInputValue('#pid-min-temp', data.pid.minTemp, {
|
||||
"min": 0,
|
||||
"max": data.system.unitSystem == 0 ? 99 : 211
|
||||
"min": data.equitherm.enable ? (data.system.unitSystem == 0 ? -100 : -146) : (data.system.unitSystem == 0 ? 0 : 32),
|
||||
"max": (data.system.unitSystem == 0 ? 99 : 211)
|
||||
});
|
||||
setInputValue('#pid-max-temp', data.pid.maxTemp, {
|
||||
"min": 1,
|
||||
"max": data.system.unitSystem == 0 ? 100 : 212
|
||||
"min": (data.system.unitSystem == 0 ? 0 : 33),
|
||||
"max": (data.system.unitSystem == 0 ? 100 : 212)
|
||||
});
|
||||
setBusy('#pid-settings-busy', '#pid-settings', false);
|
||||
};
|
||||
|
||||