mirror of
https://github.com/Laxilef/OTGateway.git
synced 2025-12-13 19:54:28 +05:00
refactor: reworked emergency mode; reworked hysteresis algorithm; improved detection of connection state for MANUAL & BOILER type sensors
This commit is contained in:
@@ -105,6 +105,14 @@ protected:
|
||||
tMqtt->disable();
|
||||
}
|
||||
|
||||
if (settings.sensors.indoor.type == SensorType::MANUAL) {
|
||||
vars.sensors.indoor.connected = !settings.mqtt.enable || vars.states.mqtt;
|
||||
}
|
||||
|
||||
if (settings.sensors.outdoor.type == SensorType::MANUAL) {
|
||||
vars.sensors.outdoor.connected = !settings.mqtt.enable || vars.states.mqtt;
|
||||
}
|
||||
|
||||
} else {
|
||||
if (this->telnetStarted) {
|
||||
telnetStream->stop();
|
||||
@@ -114,6 +122,14 @@ protected:
|
||||
if (tMqtt->isEnabled()) {
|
||||
tMqtt->disable();
|
||||
}
|
||||
|
||||
if (settings.sensors.indoor.type == SensorType::MANUAL) {
|
||||
vars.sensors.indoor.connected = false;
|
||||
}
|
||||
|
||||
if (settings.sensors.outdoor.type == SensorType::MANUAL) {
|
||||
vars.sensors.outdoor.connected = false;
|
||||
}
|
||||
}
|
||||
this->yield();
|
||||
|
||||
@@ -189,42 +205,22 @@ protected:
|
||||
}
|
||||
|
||||
void emergency() {
|
||||
if (!settings.emergency.enable && vars.states.emergency) {
|
||||
this->emergencyDetected = false;
|
||||
vars.states.emergency = false;
|
||||
|
||||
Log.sinfoln(FPSTR(L_MAIN), F("Emergency mode disabled"));
|
||||
}
|
||||
|
||||
if (!settings.emergency.enable) {
|
||||
return;
|
||||
}
|
||||
|
||||
// flags
|
||||
uint8_t emergencyFlags = 0b00000000;
|
||||
|
||||
// set network flag
|
||||
if (settings.emergency.onNetworkFault && !network->isConnected()) {
|
||||
// set outdoor sensor flag
|
||||
if (settings.equitherm.enable && !vars.sensors.outdoor.connected) {
|
||||
emergencyFlags |= 0b00000001;
|
||||
}
|
||||
|
||||
// set mqtt flag
|
||||
if (settings.emergency.onMqttFault && (!tMqtt->isEnabled() || !tMqtt->isConnected())) {
|
||||
// set indoor sensor flag
|
||||
if (!settings.equitherm.enable && settings.pid.enable && !vars.sensors.indoor.connected) {
|
||||
emergencyFlags |= 0b00000010;
|
||||
}
|
||||
|
||||
// set outdoor sensor flag
|
||||
if (settings.sensors.outdoor.type == SensorType::DS18B20 || settings.sensors.outdoor.type == SensorType::BLUETOOTH) {
|
||||
if (settings.emergency.onOutdoorSensorDisconnect && !vars.sensors.outdoor.connected) {
|
||||
emergencyFlags |= 0b00000100;
|
||||
}
|
||||
}
|
||||
|
||||
// set indoor sensor flag
|
||||
if (settings.sensors.indoor.type == SensorType::DS18B20 || settings.sensors.indoor.type == SensorType::BLUETOOTH) {
|
||||
if (settings.emergency.onIndoorSensorDisconnect && !vars.sensors.indoor.connected) {
|
||||
emergencyFlags |= 0b00001000;
|
||||
}
|
||||
// set indoor sensor flag for OT native heating control
|
||||
if (settings.opentherm.nativeHeatingControl && !vars.sensors.indoor.connected) {
|
||||
emergencyFlags |= 0b00000100;
|
||||
}
|
||||
|
||||
// if any flags is true
|
||||
|
||||
Reference in New Issue