From a6673174128a3cae61cac2eaeaf6154e772d9f01 Mon Sep 17 00:00:00 2001 From: Yurii Date: Sun, 18 May 2025 16:01:04 +0300 Subject: [PATCH] refactor: increased max. target indoor temp. from 30 to 40 degrees (for control by return temperature) --- src/defines.h | 2 +- src_data/pages/settings.html | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-) diff --git a/src/defines.h b/src/defines.h index f43ea4d..f5e0de9 100644 --- a/src/defines.h +++ b/src/defines.h @@ -16,7 +16,7 @@ #define THERMOSTAT_INDOOR_DEFAULT_TEMP 20 #define THERMOSTAT_INDOOR_MIN_TEMP 5 -#define THERMOSTAT_INDOOR_MAX_TEMP 30 +#define THERMOSTAT_INDOOR_MAX_TEMP 40 #define DEFAULT_NTC_NOMINAL_RESISTANCE 10000.0f #define DEFAULT_NTC_NOMINAL_TEMP 25.0f diff --git a/src_data/pages/settings.html b/src_data/pages/settings.html index 4452297..453a894 100644 --- a/src_data/pages/settings.html +++ b/src_data/pages/settings.html @@ -869,7 +869,7 @@ if (data.opentherm.options.nativeHeatingControl) { setInputValue("[name='emergency[target]']", data.emergency.target, { "min": data.system.unitSystem == 0 ? 5 : 41, - "max": data.system.unitSystem == 0 ? 30 : 86 + "max": data.system.unitSystem == 0 ? 40 : 86 }); } else {