mirror of
https://github.com/Laxilef/OTGateway.git
synced 2025-12-11 18:54:28 +05:00
fix: revert default value of slave max modulation; always set max modulation level
Baxi Ampera resets the maximum modulation level to 0 when the heating is turned off
This commit is contained in:
@@ -687,19 +687,17 @@ protected:
|
|||||||
targetMaxModulation = settings.dhw.maxModulation;
|
targetMaxModulation = settings.dhw.maxModulation;
|
||||||
}
|
}
|
||||||
|
|
||||||
if (vars.slave.modulation.max != targetMaxModulation) {
|
if (this->setMaxModulationLevel(targetMaxModulation)) {
|
||||||
if (this->setMaxModulationLevel(targetMaxModulation)) {
|
Log.snoticeln(
|
||||||
Log.snoticeln(
|
FPSTR(L_OT), F("Set max modulation: %hhu%% (response: %hhu%%)"),
|
||||||
FPSTR(L_OT), F("Set max modulation: %hhu%% (response: %hhu%%)"),
|
targetMaxModulation, vars.slave.modulation.max
|
||||||
targetMaxModulation, vars.slave.modulation.max
|
);
|
||||||
);
|
|
||||||
|
|
||||||
} else {
|
} else {
|
||||||
Log.swarningln(
|
Log.swarningln(
|
||||||
FPSTR(L_OT), F("Failed set max modulation: %hhu%% (response: %hhu%%)"),
|
FPSTR(L_OT), F("Failed set max modulation: %hhu%% (response: %hhu%%)"),
|
||||||
targetMaxModulation, vars.slave.modulation.max
|
targetMaxModulation, vars.slave.modulation.max
|
||||||
);
|
);
|
||||||
}
|
|
||||||
}
|
}
|
||||||
|
|
||||||
// Update modulation level
|
// Update modulation level
|
||||||
|
|||||||
@@ -328,7 +328,7 @@ struct Variables {
|
|||||||
struct {
|
struct {
|
||||||
uint8_t current = 0;
|
uint8_t current = 0;
|
||||||
uint8_t min = 0;
|
uint8_t min = 0;
|
||||||
uint8_t max = 0;
|
uint8_t max = 100;
|
||||||
} modulation;
|
} modulation;
|
||||||
|
|
||||||
struct {
|
struct {
|
||||||
|
|||||||
Reference in New Issue