mirror of
https://github.com/Laxilef/OTGateway.git
synced 2025-12-13 03:34:28 +05:00
feat: added native heating control by boiler; refactoring; emergency settings removed from HA
This commit is contained in:
@@ -101,7 +101,8 @@ protected:
|
||||
}
|
||||
|
||||
void loop() {
|
||||
static byte currentHeatingTemp, currentDhwTemp = 0;
|
||||
static float currentHeatingTemp = 0.0f;
|
||||
static float currentDhwTemp = 0.0f;
|
||||
|
||||
if (this->instanceInGpio != settings.opentherm.inGpio || this->instanceOutGpio != settings.opentherm.outGpio) {
|
||||
this->setup();
|
||||
@@ -351,18 +352,13 @@ protected:
|
||||
|
||||
|
||||
// Update DHW temp
|
||||
byte newDhwTemp = settings.dhw.target;
|
||||
if (settings.opentherm.dhwPresent && settings.dhw.enable && (this->needSetDhwTemp() || newDhwTemp != currentDhwTemp)) {
|
||||
if (newDhwTemp < settings.dhw.minTemp || newDhwTemp > settings.dhw.maxTemp) {
|
||||
newDhwTemp = constrain(newDhwTemp, settings.dhw.minTemp, settings.dhw.maxTemp);
|
||||
}
|
||||
|
||||
float convertedTemp = convertTemp(newDhwTemp, settings.system.unitSystem, settings.opentherm.unitSystem);
|
||||
Log.sinfoln(FPSTR(L_OT_DHW), F("Set temp: %u (converted: %.2f)"), newDhwTemp, convertedTemp);
|
||||
if (settings.opentherm.dhwPresent && settings.dhw.enable && (this->needSetDhwTemp() || fabs(settings.dhw.target - currentDhwTemp) > 0.0001f)) {
|
||||
float convertedTemp = convertTemp(settings.dhw.target, settings.system.unitSystem, settings.opentherm.unitSystem);
|
||||
Log.sinfoln(FPSTR(L_OT_DHW), F("Set temp: %.2f (converted: %.2f)"), settings.dhw.target, convertedTemp);
|
||||
|
||||
// Set DHW temp
|
||||
if (this->instance->setDhwTemp(convertedTemp)) {
|
||||
currentDhwTemp = newDhwTemp;
|
||||
currentDhwTemp = settings.dhw.target;
|
||||
this->dhwSetTempTime = millis();
|
||||
|
||||
} else {
|
||||
@@ -372,57 +368,94 @@ protected:
|
||||
// Set DHW temp to CH2
|
||||
if (settings.opentherm.dhwToCh2) {
|
||||
if (!this->instance->setHeatingCh2Temp(convertedTemp)) {
|
||||
Log.swarningln(FPSTR(L_OT_DHW), F("Failed set ch2 temp"));
|
||||
Log.swarningln(FPSTR(L_OT_DHW), F("Failed set CH2 temp"));
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
// Update heating temp
|
||||
if (heatingEnabled && (this->needSetHeatingTemp() || fabs(vars.parameters.heatingSetpoint - currentHeatingTemp) > 0.0001)) {
|
||||
float convertedTemp = convertTemp(vars.parameters.heatingSetpoint, settings.system.unitSystem, settings.opentherm.unitSystem);
|
||||
Log.sinfoln(FPSTR(L_OT_HEATING), F("Set temp: %u (converted: %.2f)"), vars.parameters.heatingSetpoint, convertedTemp);
|
||||
// Native heating control
|
||||
if (settings.opentherm.nativeHeatingControl) {
|
||||
// Set current indoor temp
|
||||
float indoorTemp = 0.0f;
|
||||
float convertedTemp = 0.0f;
|
||||
|
||||
// Set max heating temp
|
||||
if (this->setMaxHeatingTemp(convertedTemp)) {
|
||||
currentHeatingTemp = vars.parameters.heatingSetpoint;
|
||||
this->heatingSetTempTime = millis();
|
||||
|
||||
} else {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set max heating temp"));
|
||||
if (!vars.states.emergency || settings.sensors.indoor.type != SensorType::MANUAL) {
|
||||
indoorTemp = vars.temperatures.indoor;
|
||||
convertedTemp = convertTemp(indoorTemp, settings.system.unitSystem, settings.opentherm.unitSystem);
|
||||
}
|
||||
|
||||
// Set heating temp
|
||||
if (this->instance->setHeatingCh1Temp(convertedTemp)) {
|
||||
currentHeatingTemp = vars.parameters.heatingSetpoint;
|
||||
this->heatingSetTempTime = millis();
|
||||
|
||||
} else {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set CH1 temp"));
|
||||
Log.sinfoln(FPSTR(L_OT_HEATING), F("Set current indoor temp: %.2f (converted: %.2f)"), indoorTemp, convertedTemp);
|
||||
if (!this->instance->setRoomTemp(convertedTemp)) {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set current indoor temp"));
|
||||
}
|
||||
|
||||
// Set heating temp to CH2
|
||||
if (settings.opentherm.heatingCh1ToCh2) {
|
||||
if (!this->instance->setHeatingCh2Temp(convertedTemp)) {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set CH2 temp"));
|
||||
// Set target indoor temp
|
||||
if (this->needSetHeatingTemp() || fabs(vars.parameters.heatingSetpoint - currentHeatingTemp) > 0.0001f) {
|
||||
convertedTemp = convertTemp(vars.parameters.heatingSetpoint, settings.system.unitSystem, settings.opentherm.unitSystem);
|
||||
Log.sinfoln(FPSTR(L_OT_HEATING), F("Set target indoor temp: %.2f (converted: %.2f)"), vars.parameters.heatingSetpoint, convertedTemp);
|
||||
|
||||
if (this->instance->setRoomSetpoint(convertedTemp)) {
|
||||
currentHeatingTemp = vars.parameters.heatingSetpoint;
|
||||
this->heatingSetTempTime = millis();
|
||||
|
||||
} else {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set target indoor temp"));
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
// Hysteresis
|
||||
// Only if enabled PID or/and Equitherm
|
||||
if (settings.heating.hysteresis > 0 && (!vars.states.emergency || settings.emergency.usePid) && (settings.equitherm.enable || settings.pid.enable)) {
|
||||
float halfHyst = settings.heating.hysteresis / 2;
|
||||
if (this->pump && vars.temperatures.indoor - settings.heating.target + 0.0001 >= halfHyst) {
|
||||
this->pump = false;
|
||||
|
||||
} else if (!this->pump && vars.temperatures.indoor - settings.heating.target - 0.0001 <= -(halfHyst)) {
|
||||
// force enable pump
|
||||
if (!this->pump) {
|
||||
this->pump = true;
|
||||
}
|
||||
|
||||
} else if (!this->pump) {
|
||||
this->pump = true;
|
||||
} else {
|
||||
// Update heating temp
|
||||
if (heatingEnabled && (this->needSetHeatingTemp() || fabs(vars.parameters.heatingSetpoint - currentHeatingTemp) > 0.0001f)) {
|
||||
float convertedTemp = convertTemp(vars.parameters.heatingSetpoint, settings.system.unitSystem, settings.opentherm.unitSystem);
|
||||
Log.sinfoln(FPSTR(L_OT_HEATING), F("Set temp: %.2f (converted: %.2f)"), vars.parameters.heatingSetpoint, convertedTemp);
|
||||
|
||||
// Set max heating temp
|
||||
if (this->setMaxHeatingTemp(convertedTemp)) {
|
||||
currentHeatingTemp = vars.parameters.heatingSetpoint;
|
||||
this->heatingSetTempTime = millis();
|
||||
|
||||
} else {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set max heating temp"));
|
||||
}
|
||||
|
||||
// Set heating temp
|
||||
if (this->instance->setHeatingCh1Temp(convertedTemp)) {
|
||||
currentHeatingTemp = vars.parameters.heatingSetpoint;
|
||||
this->heatingSetTempTime = millis();
|
||||
|
||||
} else {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set CH1 temp"));
|
||||
}
|
||||
|
||||
// Set heating temp to CH2
|
||||
if (settings.opentherm.heatingCh1ToCh2) {
|
||||
if (!this->instance->setHeatingCh2Temp(convertedTemp)) {
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed set CH2 temp"));
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
// Hysteresis
|
||||
// Only if enabled PID or/and Equitherm
|
||||
if (settings.heating.hysteresis > 0 && (!vars.states.emergency || settings.emergency.usePid) && (settings.equitherm.enable || settings.pid.enable)) {
|
||||
float halfHyst = settings.heating.hysteresis / 2;
|
||||
if (this->pump && vars.temperatures.indoor - settings.heating.target + 0.0001f >= halfHyst) {
|
||||
this->pump = false;
|
||||
|
||||
} else if (!this->pump && vars.temperatures.indoor - settings.heating.target - 0.0001f <= -(halfHyst)) {
|
||||
this->pump = true;
|
||||
}
|
||||
|
||||
} else if (!this->pump) {
|
||||
this->pump = true;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue