feat: expose smart heating control across device interfaces
Rename indoor_temp_control to smart_control across firmware, REST, the dashboard and Home Assistant. Publish state/master/heating/smart_control over MQTT and remove the redundant state/master/mqtt/connected topic.
This commit is contained in:
1 parent
9ff1bd14f5
commit
7e1d0ddff2
7 files changed
+16
-16
No files matched your search
+5
-5
@@ -1336,11 +1336,11 @@ static bool normalizeHeatingFreezeBounds(HeatingSettings& dst) {
|
||||
static SettingResult setHeatingTarget(HeatingSettings& dst, float value) {
|
||||
bool changed = false;
|
||||
|
||||
bool indoorTempControl = settings.equitherm.enabled || settings.pid.enabled || settings.opentherm.options.nativeOTC;
|
||||
float minTemp = indoorTempControl
|
||||
bool smartControl = settings.equitherm.enabled || settings.pid.enabled || settings.opentherm.options.nativeOTC;
|
||||
float minTemp = smartControl
|
||||
? THERMOSTAT_INDOOR_MIN_TEMP
|
||||
: dst.minTemp;
|
||||
float maxTemp = indoorTempControl
|
||||
float maxTemp = smartControl
|
||||
? THERMOSTAT_INDOOR_MAX_TEMP
|
||||
: dst.maxTemp;
|
||||
|
||||
@@ -1353,7 +1353,7 @@ static SettingResult setHeatingTarget(HeatingSettings& dst, float value) {
|
||||
);
|
||||
|
||||
if (!valid) {
|
||||
value = indoorTempControl ? THERMOSTAT_INDOOR_DEFAULT_TEMP : DEFAULT_HEATING_TARGET_TEMP;
|
||||
value = smartControl ? THERMOSTAT_INDOOR_DEFAULT_TEMP : DEFAULT_HEATING_TARGET_TEMP;
|
||||
}
|
||||
|
||||
value = constrain(value, minTemp, maxTemp);
|
||||
@@ -3405,7 +3405,7 @@ JsonVariant toJson(const Variables& src, JsonVariant dst) {
|
||||
auto mHeating = master[S_HEATING].to<JsonObject>();
|
||||
mHeating[S_ENABLED] = src.master.heating.enabled;
|
||||
mHeating[S_BLOCKING] = src.master.heating.blocking;
|
||||
mHeating[S_INDOOR_TEMP_CONTROL] = src.master.heating.indoorTempControl;
|
||||
mHeating[S_SMART_CONTROL] = src.master.heating.smartControl;
|
||||
mHeating[S_OVERHEAT] = src.master.heating.overheat;
|
||||
mHeating[S_FREEZING] = src.master.heating.freezing;
|
||||
mHeating[S_SETPOINT_TEMP] = roundf((src.master.heating.setpointTemp == 0 ? 0 : convertTemp(src.master.heating.setpointTemp, UnitSystem::METRIC, settings.system.unitSystem)), 2);
|
||||
|
||||
@@ -608,7 +608,7 @@ void publishHaEntity(HaEntity entityId, bool remove) {
|
||||
if (!remove) {
|
||||
climate->icon = "mdi:radiator";
|
||||
climate->enabledByDefault = true;
|
||||
climate->currentTemperatureTopic = vars.master.heating.indoorTempControl
|
||||
climate->currentTemperatureTopic = vars.master.heating.smartControl
|
||||
? "~/state/master/heating/indoor_temp"
|
||||
: "~/state/master/heating/current_temp";
|
||||
climate->temperatureCommandTopic = "~/settings/heating/target/set";
|
||||
|
||||
+4
-4
@@ -247,6 +247,7 @@ static void publishSlaveState() {
|
||||
static void publishMasterState() {
|
||||
publishValue(mqttTopic("state/master/heating/enabled"), vars.master.heating.enabled);
|
||||
publishValue(mqttTopic("state/master/heating/blocking"), vars.master.heating.blocking);
|
||||
publishValue(mqttTopic("state/master/heating/smart_control"), vars.master.heating.smartControl);
|
||||
publishValue(mqttTopic("state/master/heating/overheat"), vars.master.heating.overheat);
|
||||
publishValue(mqttTopic("state/master/heating/freezing"), vars.master.heating.freezing);
|
||||
publishValue(
|
||||
@@ -284,7 +285,6 @@ static void publishMasterState() {
|
||||
publishValue(mqttTopic("state/master/dhw/max_temp"), convertTemp(settings.dhw.maxTemp, UnitSystem::METRIC, settings.system.unitSystem), 2);
|
||||
publishValue(mqttTopic("state/master/network/connected"), isNetworkConnected());
|
||||
publishValue(mqttTopic("state/master/network/rssi"), std::to_string(vars.network.rssi));
|
||||
publishValue(mqttTopic("state/master/mqtt/connected"), isMqttConnected());
|
||||
publishValue(mqttTopic("state/master/emergency/state"), vars.emergency.state);
|
||||
publishValue(mqttTopic("state/master/ext_pump/state"), vars.externalPump.state);
|
||||
publishValue(mqttTopic("state/master/cascade_control/input"), vars.cascadeControl.input);
|
||||
@@ -762,7 +762,7 @@ Task mqttConfigureTask("Configure MQTT", Task::Type::ONCE, [](void*) {
|
||||
static uint8_t heatingMinTemp = vars.slave.heating.minTemp;
|
||||
static uint8_t heatingMaxTemp = vars.slave.heating.maxTemp;
|
||||
static bool dhwSupport = settings.opentherm.options.dhwSupport;
|
||||
static bool indoorTempControl = vars.master.heating.indoorTempControl;
|
||||
static bool smartControl = vars.master.heating.smartControl;
|
||||
static float heatingMinSetpointTemp = vars.master.heating.minTemp;
|
||||
static float heatingMaxSetpointTemp = vars.master.heating.maxTemp;
|
||||
static uint8_t dhwMinTemp = settings.dhw.minTemp;
|
||||
@@ -827,8 +827,8 @@ Task mqttConfigureTask("Configure MQTT", Task::Type::ONCE, [](void*) {
|
||||
.set(HA_ENTITY_DHW_OVERHEAT);
|
||||
}
|
||||
|
||||
if (indoorTempControl != vars.master.heating.indoorTempControl) {
|
||||
indoorTempControl = vars.master.heating.indoorTempControl;
|
||||
if (smartControl != vars.master.heating.smartControl) {
|
||||
smartControl = vars.master.heating.smartControl;
|
||||
mqttHaPendingEntities.set(HA_ENTITY_HEATING_CLIMATE);
|
||||
}
|
||||
|
||||
|
||||
+2
-2
@@ -188,12 +188,12 @@ static Task regulatorTask("Regulator", [](void*) {
|
||||
}
|
||||
|
||||
if (settings.equitherm.enabled || settings.pid.enabled || settings.opentherm.options.nativeOTC) {
|
||||
vars.master.heating.indoorTempControl = true;
|
||||
vars.master.heating.smartControl = true;
|
||||
vars.master.heating.minTemp = THERMOSTAT_INDOOR_MIN_TEMP;
|
||||
vars.master.heating.maxTemp = THERMOSTAT_INDOOR_MAX_TEMP;
|
||||
|
||||
} else {
|
||||
vars.master.heating.indoorTempControl = false;
|
||||
vars.master.heating.smartControl = false;
|
||||
vars.master.heating.minTemp = settings.heating.minTemp;
|
||||
vars.master.heating.maxTemp = settings.heating.maxTemp;
|
||||
}
|
||||
|
||||