mirror of
https://github.com/Laxilef/OTGateway.git
synced 2025-12-11 10:44:29 +05:00
Merge pull request #17 from mennodegraaf/ot-improvements
Improve opentherm handling
This commit is contained in:
@@ -23,6 +23,7 @@ protected:
|
|||||||
unsigned short heatingSetTempInterval = 60000;
|
unsigned short heatingSetTempInterval = 60000;
|
||||||
|
|
||||||
bool pump = true;
|
bool pump = true;
|
||||||
|
bool prevOtStatus = false;
|
||||||
unsigned long prevUpdateNonEssentialVars = 0;
|
unsigned long prevUpdateNonEssentialVars = 0;
|
||||||
unsigned long startupTime = millis();
|
unsigned long startupTime = millis();
|
||||||
unsigned long dhwSetTempTime = 0;
|
unsigned long dhwSetTempTime = 0;
|
||||||
@@ -57,43 +58,43 @@ protected:
|
|||||||
#endif
|
#endif
|
||||||
}
|
}
|
||||||
|
|
||||||
|
void initBoiler() {
|
||||||
|
// Not all boilers support these, only try once when the boiler becomes connected
|
||||||
|
if (updateSlaveVersion()) {
|
||||||
|
Log.straceln(FPSTR(S_OT), F("Slave version: %u, type: %u"), vars.parameters.slaveVersion, vars.parameters.slaveType);
|
||||||
|
|
||||||
|
} else {
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Get slave version failed"));
|
||||||
|
}
|
||||||
|
|
||||||
|
// 0x013F
|
||||||
|
if (setMasterVersion(0x3F, 0x01)) {
|
||||||
|
Log.straceln(FPSTR(S_OT), F("Master version: %u, type: %u"), vars.parameters.masterVersion, vars.parameters.masterType);
|
||||||
|
|
||||||
|
} else {
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Set master version failed"));
|
||||||
|
}
|
||||||
|
|
||||||
|
if (updateSlaveConfig()) {
|
||||||
|
Log.straceln(FPSTR(S_OT), F("Slave member id: %u, flags: %u"), vars.parameters.slaveMemberId, vars.parameters.slaveFlags);
|
||||||
|
|
||||||
|
} else {
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Get slave config failed"));
|
||||||
|
}
|
||||||
|
|
||||||
|
if (setMasterConfig(settings.opentherm.memberIdCode & 0xFF, (settings.opentherm.memberIdCode & 0xFFFF) >> 8)) {
|
||||||
|
Log.straceln(FPSTR(S_OT), F("Master member id: %u, flags: %u"), vars.parameters.masterMemberId, vars.parameters.masterFlags);
|
||||||
|
|
||||||
|
} else {
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Set master config failed"));
|
||||||
|
}
|
||||||
|
|
||||||
|
}
|
||||||
|
|
||||||
void loop() {
|
void loop() {
|
||||||
static byte currentHeatingTemp, currentDhwTemp = 0;
|
static byte currentHeatingTemp, currentDhwTemp = 0;
|
||||||
unsigned long localResponse;
|
unsigned long localResponse;
|
||||||
|
|
||||||
if (millis() - prevUpdateNonEssentialVars > 60000) {
|
|
||||||
if (updateSlaveVersion()) {
|
|
||||||
Log.straceln(FPSTR(S_OT), F("Slave version: %u, type: %u"), vars.parameters.slaveVersion, vars.parameters.slaveType);
|
|
||||||
|
|
||||||
} else {
|
|
||||||
Log.swarningln(FPSTR(S_OT), F("Get slave version failed"));
|
|
||||||
}
|
|
||||||
|
|
||||||
// 0x013F
|
|
||||||
if (setMasterVersion(0x3F, 0x01)) {
|
|
||||||
Log.straceln(FPSTR(S_OT), F("Master version: %u, type: %u"), vars.parameters.masterVersion, vars.parameters.masterType);
|
|
||||||
|
|
||||||
} else {
|
|
||||||
Log.swarningln(FPSTR(S_OT), F("Set master version failed"));
|
|
||||||
}
|
|
||||||
|
|
||||||
if (updateSlaveConfig()) {
|
|
||||||
Log.straceln(FPSTR(S_OT), F("Slave member id: %u, flags: %u"), vars.parameters.slaveMemberId, vars.parameters.slaveFlags);
|
|
||||||
|
|
||||||
} else {
|
|
||||||
Log.swarningln(FPSTR(S_OT), F("Get slave config failed"));
|
|
||||||
}
|
|
||||||
|
|
||||||
if (setMasterConfig(settings.opentherm.memberIdCode & 0xFF, (settings.opentherm.memberIdCode & 0xFFFF) >> 8)) {
|
|
||||||
Log.straceln(FPSTR(S_OT), F("Master member id: %u, flags: %u"), vars.parameters.masterMemberId, vars.parameters.masterFlags);
|
|
||||||
|
|
||||||
} else {
|
|
||||||
Log.swarningln(FPSTR(S_OT), F("Set master config failed"));
|
|
||||||
}
|
|
||||||
|
|
||||||
//yield();
|
|
||||||
}
|
|
||||||
|
|
||||||
bool heatingEnabled = (vars.states.emergency || settings.heating.enable) && pump && isReady();
|
bool heatingEnabled = (vars.states.emergency || settings.heating.enable) && pump && isReady();
|
||||||
bool heatingCh2Enabled = settings.opentherm.heatingCh2Enabled;
|
bool heatingCh2Enabled = settings.opentherm.heatingCh2Enabled;
|
||||||
if (settings.opentherm.heatingCh1ToCh2) {
|
if (settings.opentherm.heatingCh1ToCh2) {
|
||||||
@@ -115,6 +116,21 @@ protected:
|
|||||||
|
|
||||||
if (!ot->isValidResponse(localResponse)) {
|
if (!ot->isValidResponse(localResponse)) {
|
||||||
Log.swarningln(FPSTR(S_OT), F("Invalid response after setBoilerStatus: %s"), ot->statusToString(ot->getLastResponseStatus()));
|
Log.swarningln(FPSTR(S_OT), F("Invalid response after setBoilerStatus: %s"), ot->statusToString(ot->getLastResponseStatus()));
|
||||||
|
}
|
||||||
|
|
||||||
|
if (vars.states.otStatus && !this->prevOtStatus) {
|
||||||
|
this->prevOtStatus = vars.states.otStatus;
|
||||||
|
|
||||||
|
Log.sinfoln(FPSTR(S_OT), F("Connected. Initializing"));
|
||||||
|
this->initBoiler();
|
||||||
|
|
||||||
|
} else if (!vars.states.otStatus && this->prevOtStatus) {
|
||||||
|
this->prevOtStatus = vars.states.otStatus;
|
||||||
|
Log.swarningln(FPSTR(S_OT), F("Disconnected"));
|
||||||
|
}
|
||||||
|
|
||||||
|
if (!vars.states.otStatus) {
|
||||||
|
// Boiler is disconnected, no need try setting other OT stuff
|
||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -130,8 +146,6 @@ protected:
|
|||||||
vars.states.fault = ot->isFault(localResponse);
|
vars.states.fault = ot->isFault(localResponse);
|
||||||
vars.states.diagnostic = ot->isDiagnostic(localResponse);
|
vars.states.diagnostic = ot->isDiagnostic(localResponse);
|
||||||
|
|
||||||
|
|
||||||
//
|
|
||||||
// These parameters will be updated every minute
|
// These parameters will be updated every minute
|
||||||
if (millis() - prevUpdateNonEssentialVars > 60000) {
|
if (millis() - prevUpdateNonEssentialVars > 60000) {
|
||||||
if (!heatingEnabled && settings.opentherm.modulationSyncWithHeating) {
|
if (!heatingEnabled && settings.opentherm.modulationSyncWithHeating) {
|
||||||
|
|||||||
Reference in New Issue