@@ -117,6 +117,7 @@
|
||||
|
||||
"mHeatEnabled": "Heating enabled",
|
||||
"mHeatBlocking": "Heating blocked",
|
||||
"mHeatOverheat": "Heating overheat",
|
||||
"sHeatActive": "Heating active",
|
||||
"mHeatSetpointTemp": "Heating setpoint temp",
|
||||
"mHeatTargetTemp": "Heating target temp",
|
||||
@@ -126,6 +127,7 @@
|
||||
"mHeatOutdoorTemp": "Heating, outdoor temp",
|
||||
|
||||
"mDhwEnabled": "DHW enabled",
|
||||
"mDhwOverheat": "DHW overheat",
|
||||
"sDhwActive": "DHW active",
|
||||
"mDhwTargetTemp": "DHW target temp",
|
||||
"mDhwCurrTemp": "DHW current temp",
|
||||
@@ -302,6 +304,24 @@
|
||||
"max": "Maximum temperature"
|
||||
},
|
||||
"maxModulation": "Max modulation level",
|
||||
"ohProtection": {
|
||||
"title": "Overheating protection",
|
||||
"desc": "<b>Note:</b> This feature can be useful if the built-in boiler overheating protection does not work or does not work correctly and the heat carrier boils. To disable, set 0 as <b>high</b> and <b>low</b> temperature.",
|
||||
"highTemp": {
|
||||
"title": "High temperature threshold",
|
||||
"note": "Threshold at which the burner will be forcibly switched off"
|
||||
},
|
||||
"lowTemp": {
|
||||
"title": "Low temperature threshold",
|
||||
"note": "Threshold at which the burner can be turned on again"
|
||||
}
|
||||
},
|
||||
"freezeProtection": {
|
||||
"title": "Freeze protection",
|
||||
"desc": "Heating will be forced to turn on if the heat carrier or indoor temperature drops below <b>Low temperature</b> during <b>Waiting time</b>.",
|
||||
"lowTemp": "Low temperature threshold",
|
||||
"thresholdTime": "Waiting time <small>(sec)</small>"
|
||||
},
|
||||
|
||||
"portal": {
|
||||
"login": "Login",
|
||||
@@ -410,7 +430,8 @@
|
||||
},
|
||||
|
||||
"options": {
|
||||
"desc": "Options",
|
||||
"title": "Options (additional settings)",
|
||||
"desc": "Options can change the logic of the boiler. Not all options are documented in the protocol, so the same option can have different effects on different boilers.<br /><b>Note:</b> There is no need to change anything if everything works well.",
|
||||
"dhwSupport": "DHW support",
|
||||
"coolingSupport": "Cooling support",
|
||||
"summerWinterMode": "Summer/winter mode",
|
||||
@@ -419,6 +440,7 @@
|
||||
"heatingToCh2": "Duplicate heating to CH2",
|
||||
"dhwToCh2": "Duplicate DHW to CH2",
|
||||
"dhwBlocking": "DHW blocking",
|
||||
"dhwStateAsDhwBlocking": "DHW state as DHW blocking",
|
||||
"maxTempSyncWithTargetTemp": "Sync max heating temp with target temp",
|
||||
"getMinMaxTemp": "Get min/max temp from boiler",
|
||||
"ignoreDiagState": "Ignore diag state",
|
||||
|
||||