fix naming

This commit is contained in:
Yurii
2023-11-22 23:04:34 +03:00
parent 18acf059fc
commit 44fdff61bd
4 changed files with 66 additions and 27 deletions

View File

@@ -90,34 +90,51 @@ protected:
Log.straceln("OT", "Master type: %u, version: %u", vars.parameters.masterType, vars.parameters.masterVersion);
Log.straceln("OT", "Slave type: %u, version: %u", vars.parameters.slaveType, vars.parameters.slaveVersion);
// DHW min/max temp
if (settings.opentherm.dhwPresent) {
if (updateMinMaxDhwTemp()) {
if (settings.dhw.minTemp < vars.parameters.dhwMinTemp) {
settings.dhw.minTemp = vars.parameters.dhwMinTemp;
Log.snoticeln("OT.DHW", "Updated min temp: %d", settings.dhw.minTemp);
}
if (settings.dhw.maxTemp > vars.parameters.dhwMaxTemp) {
settings.dhw.maxTemp = vars.parameters.dhwMaxTemp;
Log.snoticeln("OT.DHW", "Updated max temp: %d", settings.dhw.maxTemp);
}
} else {
Log.swarningln("OT.DHW", "Failed get min/max temp");
}
if (settings.dhw.minTemp >= settings.dhw.maxTemp) {
settings.dhw.minTemp = 30;
settings.dhw.maxTemp = 60;
}
}
// Heating min/max temp
if (updateMinMaxHeatingTemp()) {
if (settings.heating.minTemp < vars.parameters.heatingMinTemp) {
settings.heating.minTemp = vars.parameters.heatingMinTemp;
Log.snoticeln("OT.HEATING", "Updated min temp: %d", settings.heating.minTemp);
}
if (settings.heating.maxTemp > vars.parameters.heatingMaxTemp) {
settings.heating.maxTemp = vars.parameters.heatingMaxTemp;
Log.snoticeln("OT.HEATING", "Updated max temp: %d", settings.heating.maxTemp);
}
} else {
Log.swarningln("OT.HEATING", "Failed get min/max temp");
}
if (settings.heating.minTemp >= settings.heating.maxTemp) {
settings.heating.minTemp = 20;
settings.heating.maxTemp = 90;
}
// force
setMaxHeatingTemp(settings.heating.maxTemp);
@@ -152,7 +169,7 @@ protected:
yield();
// fault reset action
if (vars.actions.faultReset) {
if (vars.actions.resetFault) {
if (vars.states.fault) {
if (ot->sendBoilerReset()) {
Log.sinfoln("OT", "Boiler fault reset successfully");
@@ -162,12 +179,12 @@ protected:
}
}
vars.actions.faultReset = false;
vars.actions.resetFault = false;
yield();
}
// diag reset action
if (vars.actions.diagnosticReset) {
if (vars.actions.resetDiagnostic) {
if (vars.states.diagnostic) {
if (ot->sendServiceReset()) {
Log.sinfoln("OT", "Boiler diagnostic reset successfully");
@@ -177,7 +194,7 @@ protected:
}
}
vars.actions.diagnosticReset = false;
vars.actions.resetDiagnostic = false;
yield();
}