@@ -243,6 +243,7 @@
|
||||
"otDhwBurnerHours": "OpenTherm, number of burner operating hours (DHW)",
|
||||
"otHeatingPumpHours": "OpenTherm, number of pump operating hours (heating)",
|
||||
"otDhwPumpHours": "OpenTherm, number of pump operating hours (DHW)",
|
||||
"otCoolingHours": "OpenTherm, number of cooling hours",
|
||||
|
||||
"ntcTemp": "NTC sensor",
|
||||
"dallasTemp": "DALLAS sensor",
|
||||
@@ -352,7 +353,16 @@
|
||||
},
|
||||
|
||||
"heating": {
|
||||
"hyst": "Hysteresis <small>(in degrees)</small>",
|
||||
"hyst": {
|
||||
"title": "Hysteresis",
|
||||
"desc": "Hysteresis is useful for maintaining a set indoor temp (when using «Equitherm» and/or «PID»). Forces disable heating when <code>current indoor > target + value</code> and enable heating when <code>current indoor < (target - value)</code>.",
|
||||
"value": "Value <small>(in degrees)</small>",
|
||||
"action": {
|
||||
"title": "Action",
|
||||
"disableHeating": "Disable heating",
|
||||
"set0target": "Set null target"
|
||||
}
|
||||
},
|
||||
"turboFactor": "Turbo mode coeff."
|
||||
},
|
||||
|
||||
@@ -367,11 +377,26 @@
|
||||
},
|
||||
|
||||
"equitherm": {
|
||||
"n": "N factor",
|
||||
"k": "K factor",
|
||||
"t": {
|
||||
"slope": {
|
||||
"title": "Slope",
|
||||
"note": "Heat loss compensation. Main tuning parameter."
|
||||
},
|
||||
"exponent": {
|
||||
"title": "Exponent",
|
||||
"note": "Radiator efficiency. Typical values: <code>1.1</code> - Floor heating, <code>1.2</code> - Cast iron, <code>1.3</code> - Panel radiators, <code>1.4</code> - Convectors."
|
||||
},
|
||||
"shift": {
|
||||
"title": "Shift",
|
||||
"note": "Compensates for additional heat losses (e.g., in pipes) or extra heat sources."
|
||||
},
|
||||
"targetDiffFactor": {
|
||||
"title": "T factor",
|
||||
"note": "Not used if PID is enabled"
|
||||
"note": "Not used if PID is enabled. Adds to the setpoint the difference between the target and current indoor temp: <code>setpoint = setpoint + ((target - indoor) * T)</code>."
|
||||
},
|
||||
"chart": {
|
||||
"targetTemp": "Target indoor temperature",
|
||||
"setpointTemp": "Heat carrier temperature",
|
||||
"outdoorTemp": "Outdoor temperature"
|
||||
}
|
||||
},
|
||||
|
||||
@@ -429,12 +454,13 @@
|
||||
"autoFaultReset": "Auto fault reset <small>(not recommended!)</small>",
|
||||
"autoDiagReset": "Auto diag reset <small>(not recommended!)</small>",
|
||||
"setDateAndTime": "Set date & time on boiler",
|
||||
"immergasFix": "Fix for Immergas boilers"
|
||||
"immergasFix": "Fix for Immergas boilers",
|
||||
"alwaysSendIndoorTemp": "Send current indoor temp to boiler"
|
||||
},
|
||||
|
||||
"nativeHeating": {
|
||||
"title": "Native heating control (boiler)",
|
||||
"note": "Works <u>ONLY</u> if the boiler requires the desired room temperature and regulates the temperature of the coolant itself. Not compatible with PID and Equitherm regulators in firmware."
|
||||
"nativeOTC": {
|
||||
"title": "Native OTC mode",
|
||||
"note": "Works <u>ONLY</u> if the boiler is in OTC mode: requires and accepts the target indoor temperature and self-regulates the heat carrier temperature based on the built-in curves mode. Incompatible with PID and Equitherm."
|
||||
}
|
||||
},
|
||||
|
||||
|
||||