mirror of
https://github.com/Laxilef/OTGateway.git
synced 2025-12-12 19:24:27 +05:00
feat: added support unit systems for pressure and flow rate
This commit is contained in:
@@ -253,12 +253,13 @@ protected:
|
||||
fsSettings.update();
|
||||
Log.snoticeln(FPSTR(L_OT_HEATING), F("Updated max temp: %hhu"), settings.heating.maxTemp);
|
||||
}
|
||||
|
||||
} else {
|
||||
vars.parameters.heatingMinTemp = convertTemp(DEFAULT_HEATING_MIN_TEMP, UnitSystem::METRIC, settings.system.unitSystem);
|
||||
vars.parameters.heatingMaxTemp = convertTemp(DEFAULT_HEATING_MAX_TEMP, UnitSystem::METRIC, settings.system.unitSystem);
|
||||
|
||||
} else {
|
||||
vars.parameters.heatingMinTemp = convertTemp(DEFAULT_HEATING_MIN_TEMP, UnitSystem::METRIC, settings.system.unitSystem);
|
||||
vars.parameters.heatingMaxTemp = convertTemp(DEFAULT_HEATING_MAX_TEMP, UnitSystem::METRIC, settings.system.unitSystem);
|
||||
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed get min/max temp"));
|
||||
Log.swarningln(FPSTR(L_OT_HEATING), F("Failed get min/max temp"));
|
||||
}
|
||||
}
|
||||
|
||||
if (settings.heating.minTemp >= settings.heating.maxTemp) {
|
||||
@@ -785,12 +786,17 @@ protected:
|
||||
if (!CustomOpenTherm::isValidResponse(response)) {
|
||||
return false;
|
||||
}
|
||||
|
||||
|
||||
float value = CustomOpenTherm::getFloat(response);
|
||||
if (value > 16 && this->dhwFlowRateMultiplier != 10) {
|
||||
if (this->dhwFlowRateMultiplier != 10 && value > convertVolume(16, UnitSystem::METRIC, settings.opentherm.unitSystem)) {
|
||||
this->dhwFlowRateMultiplier = 10;
|
||||
}
|
||||
vars.sensors.dhwFlowRate = this->dhwFlowRateMultiplier == 1 ? value : value / this->dhwFlowRateMultiplier;
|
||||
|
||||
vars.sensors.dhwFlowRate = convertVolume(
|
||||
value / this->dhwFlowRateMultiplier,
|
||||
settings.opentherm.unitSystem,
|
||||
settings.system.unitSystem
|
||||
);
|
||||
|
||||
return true;
|
||||
}
|
||||
@@ -838,10 +844,15 @@ protected:
|
||||
}
|
||||
|
||||
float value = CustomOpenTherm::getFloat(response);
|
||||
if (value > 5 && this->pressureMultiplier != 10) {
|
||||
if (this->pressureMultiplier != 10 && value > convertPressure(5, UnitSystem::METRIC, settings.opentherm.unitSystem)) {
|
||||
this->pressureMultiplier = 10;
|
||||
}
|
||||
vars.sensors.pressure = this->pressureMultiplier == 1 ? value : value / this->pressureMultiplier;
|
||||
|
||||
vars.sensors.pressure = convertPressure(
|
||||
value / this->pressureMultiplier,
|
||||
settings.opentherm.unitSystem,
|
||||
settings.system.unitSystem
|
||||
);
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
Reference in New Issue