@@ -89,8 +89,8 @@ HOWEVER, it doesn't work, and will not work, with linuxcnc. As I learned,
|
|||||||
the IgH EtherCAT master needs a CoE client (CANopen over EtherCAT).
|
the IgH EtherCAT master needs a CoE client (CANopen over EtherCAT).
|
||||||
The LAN9252 in DIO mode is only an EtherCAT client and can't be turned
|
The LAN9252 in DIO mode is only an EtherCAT client and can't be turned
|
||||||
into a CoE client. And the IgH EtherCAT application interface for real-time
|
into a CoE client. And the IgH EtherCAT application interface for real-time
|
||||||
communication can not be downgraded to wotk with puer EtherCAT client,
|
communication can not be downgraded to work with a pure EtherCAT client,
|
||||||
it requires an CoE client.
|
it requires a CoE client.
|
||||||
|
|
||||||
To add CoE functionality means to add number of objects at certain positions
|
To add CoE functionality means to add number of objects at certain positions
|
||||||
in the client and that can not be done to the LAN9252. It is what it is.
|
in the client and that can not be done to the LAN9252. It is what it is.
|
||||||
|
|||||||